Astigmatism correction with toric implantable collamer lens in low and high astigmatism groups

Author:

Cano-Ortiz Antonio1,Sánchez-Ventosa Álvaro1ORCID,Membrillo Alberto1,Castillo Rosa1,Gomera Aurora1,López-Pérez María Dolores1,Villarrubia Alberto1ORCID

Affiliation:

1. H. La Arruzafa, Córdoba, Spain

Abstract

Purpose: To analyze the target induced astigmatism (TIA), surgically induced astigmatism (SIA), difference vector (DV), and correction index (CI) in the correction of astigmatism with phakic lenses, and its influence on visual acuity, and to analyze the safety and efficacy indexes of the correction of high and low power astigmatism with toric phakic lenses. Design: Retrospective comparative study. Methods: The medical records of patients that were operated on at the research center during the period were analyzed. Results were divided into Low Astigmatism Group – LAG (33 eyes) and High Astigmatism Group – HAG (93 eyes) according to the implanted toric ICL lens power. Preoperative refraction and resultant postoperative refraction were analyzed by vector analysis. Visual acuity pre and postop, with and without optical correction, were compared. Results: A total of 126 eyes were studied. The average preop refraction was −5.02 D sphere with −2.61 D cylinder. The average ICL lens power implanted was −8.31 D sphere +2.77 D cylinder. Refractive remaining was −0.01 ± 0.11 D sphere −0.15 ± 0.28 D cylinder. The arithmetic average angle of error in the astigmatism correction was 1.08°. The resultant cylinder was −0.03 ± 0.12 D and −0.19 ± 0.30 D in the low and high astigmatism groups, respectively, with a mean UDVA −0.01 ± 0.10 and 0.01 ± 0.16 and CDVA −0.03 ± 0.08 and −0.01 ± 0.17 for each group. The safety and efficacy indexes for the low astigmatism group were 1.09 ± 0.16 and 1.05 ± 0.17, respectively, with 1.11 ± 0.17 and 1.06 ± 0.16 for the high astigmatism group. Conclusions: The correction of astigmatism by the implantation of toric phakic lenses of the posterior chamber is safe and effective, independently of the amount of cylinder corrected.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3