Assessment of pupillary light reflex using dynamic pupillometry in laser-treated eyes with retinal vein occlusion

Author:

Turk Huseyin Bugra1ORCID,Bitirgen Gulfidan2ORCID,Satirtav Gunhal2,Kerimoglu Hurkan2

Affiliation:

1. Department of Ophthalmology, Gaziantep Dr. Ersin Arslan Education and Research Hospital, Gaziantep, Turkey

2. Department of Ophthalmology, Necmettin Erbakan University Meram Faculty of Medicine, Konya, Turkey

Abstract

Purpose: This study aims to evaluate the pupillary light reflex measured with dynamic pupillometry in patients who underwent retinal laser photocoagulation due to unilateral retinal vein occlusion (RVO). Methods: A total of 48 patients with unilateral RVO were included in the study. Thirty-four patients had undergone retinal laser photocoagulation while the remaining 14 patients that did not undergo laser treatment were observed for control purposes. Of the laser-treated eyes, 14 eyes (41.2%) had central RVO (CRVO) and 20 eyes (58.8%) had branch RVO (BRVO). Among the 14 patients with RVO without laser treatment, nine eyes (64.3%) had CRVO and five eyes (35.7%) had BRVO. Pupillary light reflexes were assessed with dynamic pupillometry (MonPackOne®; Metrovision, France). The parameters of the eyes with RVO were compared with that of fellow healthy eyes. Results: Mean patient age was 65.8 ± 10.4 years and median time after photocoagulation was 25.5 months. Eyes that received laser photocoagulation had lower pupil contraction amplitude ( p = 0.037), prolonged contraction latency ( p = 0.027), slower contraction velocity ( p = 0.043), and slower dilation velocity ( p < 0.001) compared to healthy fellow eyes. Subgroup analysis revealed that eyes with CRVO had lower contraction amplitude ( p = 0.013) and slower dilation velocity ( p = 0.003), and eyes with BRVO had slower dilation velocity ( p = 0.003). Non-laser-treated eyes with RVO revealed no significant difference in any of the pupillary light reflex parameters compared to fellow eyes. Conclusion: Laser-treated eyes with RVO demonstrated changes in pupillary light reflex parameters including reduced contraction amplitude, prolonged contraction latency, and slower contraction and dilation velocities measured with dynamic pupillometry.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3