Double trouble in DMEK surgery: Learning experience and review of the literature

Author:

Romano Vito12ORCID,Passaro Maria Laura34,Airaldi Matteo56ORCID,Ancona Chiara1,Pagano Luca6ORCID,Semeraro Francesco12ORCID,Pineda Roberto7

Affiliation:

1. Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy

2. Ophthalmic Unit, ASST Spedali Civili di Brescia, Piazzale Spedali Civili, 1, 25123, Brescia, Italia

3. Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples “Federico II”, Naples, Italy

4. Department of Medicine and Health Sciences “V. Tiberio”, University of Molise, Campobasso, Italy

5. Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy

6. St. Paul's Eye Unit, Royal Liverpool University Hospital, Liverpool, UK

7. Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, USA

Abstract

Purpose To report a challenging Descemet Membrane Endothelial Keratoplasty (DMEK) case, complicated by intraoperative aqueous misdirection and spontaneous anterior chamber fibrin reaction. Methods A 70-year-old female affected by corneal edema due to Fuchs endothelial dystrophy underwent a triple procedure (cataract extraction - IOL implantation - DMEK surgery) in her left eye. This report illustrates the management of the intraoperative complications of aqueous misdirection syndrome and anterior chamber fibrin reaction. Results Despite the optimal management of the posterior pressure and the thorough removal of the fibrinous reaction during the case, the DMEK graft was not completely unfolded and centred at the end of the surgical procedure. Nonetheless, the patient showed good long-term anatomical and functional recovery: at the last follow-up (2 years after surgery), central corneal thickness was 526 µm with a best corrected visual acuity of 20/25 and an endothelial cell density of 1112 cell/mm2. Conclusion Early recognition and prompt management of intraoperative aqueous misdirection syndrome and anterior chamber fibrin reaction during DMEK surgery is essential to ensure good functional and anatomical outcomes.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3