One-year post-operative comparison of visual function and patient satisfaction with trifocal and extended depth of focus intraocular lenses

Author:

Law Elizabeth M.12ORCID,Aggarwal Rajesh K.1,Buckhurst Hetal3,Kasaby Hosam E.1,Marsden Jonathan3,Shum Gary4,Buckhust Phillip J.3

Affiliation:

1. BMI Southend Hospital, Fairfax Drive, Westcliff on Sea, UK

2. Southend University Hospital NHS Trust, Westcliff on Sea, UK

3. School of Health Professions, University of Plymouth, UK

4. School of Sport Health & Wellbeing, Plymouth Marjon University, UK

Abstract

Purpose To evaluate visual performance with trifocal and extended depth of focus IOL at 1 year post-operatively. Setting BMI Southend Hospital. Design Cohort study. Methods An age-matched cohort of forty subjects bilaterally implanted with the AT LISA 839MP trifocal IOL (20 patients, 40 eyes) and the Tecnis Symfony extended depth of focus IOL (20 patients, 40 eyes) were assessed at 3–6 months and 12–18 months post-operatively. Primary outcome measures were distance (6 m), intermediate (70 cm), near visual acuity (40 cm), and analysis of defocus profiles. Secondary outcomes included contrast sensitivity, Radner reading performance, quality of vision and assessment of halos. Results Distance visual acuity (VA) and defocus areas were similar ( p = 0.07). No significant difference in intermediate VA was noted but the intermediate area of focus was greater in the EDoF (0.31 ± 0.12 LogMAR*m−1) compared to the trifocal (0.22 ± 0.08LogMAR*m−1) ( p = 0.02). However, all near metrics were significantly better in the trifocal group. 80% of trifocal subjects were spectacle independent compared to 50% EDoF subjects. Quality of vision questionnaire found no significant differences between groups, however halo scores were greater at 3–6 months in the trifocal group ( p < 0.01) but no differences were noted at 12–18 months. Conclusions Near vision is significantly better for the trifocal, thus greater levels of spectacle independence. The range of intermediate vision was greater for the EDoF but no difference in intermediate VA. In the early period, differences in contrast sensitivity and halo size/intensity were noted, however, by one-year these measures were not significantly different.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3