Ageing changes in retinal outer nuclear layer thickness and cone photoreceptor density using adaptive optics-free imaging

Author:

Matlach Juliane123ORCID,Mulholland Padraig145,Cilkova Marketa1,Chopra Reena1,Shah Nilpa1,Redmond Tony5ORCID,Dakin Steven C16,Garway-Heath David F1,Anderson Roger S14

Affiliation:

1. NIHR Biomedical Research Centre, Moorfields Eye Hospital & UCL Institute of Ophthalmology, London, UK

2. Department of Ophthalmology, University Medical Center, Johannes Gutenberg University Mainz, Mainz, Germany

3. Department of Ophthalmology, University of Leipzig, Leipzig, Germany

4. Vision Science Research Group, Ulster University, Coleraine, UK

5. School of Optometry and Vision Sciences, Cardiff University, Cardiff, UK

6. School of Optometry & Vision Science, The University of Auckland, Auckland, New Zealand

Abstract

Purpose To investigate age-related changes of the outer nuclear layer (ONL) thickness and cone density, and their associations in healthy participants using a modified, narrow scan-angle Heidelberg Retina Angiograph (HRA2). Methods Retinal cones were imaged outside the fovea at 8.8° eccentricity and cone density was compared to ONL thickness measurements obtained by Spectral-Domain Optical Coherence Tomography (SD-OCT) at the same locations. Fifty-six eyes of 56 healthy participants with a median age (interquartile range, IQR) of 37 years (29–55) were included. Results Median (IQR) cone count was 7,472 (7,188, 7,746) cones/mm2 and median (IQR) ONL thickness was 56 (52, 60) µm for healthy participants. Both cone density and ONL thickness were negatively associated with age: cone density, R2 = 0.16 (F(1,54) = 10.41, P = 0.002); ONL thickness, R2 = 0.12 (F(1,54) = 7.41, P = 0.009). No significant association was seen between cone density and ONL thickness (R2 = 0.03; F(1,54) = 1.66, P = 0.20). Conclusion Cone density was lower, and ONL thinner, in older compared to younger participants, therefore, image-based structural measures should be compared to age-related data. However, cone density and ONL thickness were not strongly associated, indicating that determinants of ONL thickness measurements other than cone density measurements, and including measurement error, have a major influence.

Funder

College of Optometrists

Dr. Werner Jackstädt-Stiftung

Fight for Sight

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3