Visual performance and impact of residual refractive errors with trifocal intraocular lenses of different aspheric design

Author:

Rementería-Capelo Laureano A1,Contreras Inés12,García-Pérez Jorge L1,Blázquez Vanesa1ORCID,Ruiz-Alcocer Javier3ORCID

Affiliation:

1. Clínica Rementería, Madrid, Spain

2. IRYCIS Grupo Oftalmología, Madrid, Spain

3. Universidad Complutense de Madrid, Madrid, Spain

Abstract

Background To assess the visual quality and the tolerance to low refractive errors of two trifocal intraocular lenses (IOL) with different amounts of spherical aberration (SA). Methods The study included patients having bilateral implantation of the AcrySof® IQ PanOptixTM (aberration-correcting) or the RayOneTM (aberration-free) Trifocal IOL. Three months after the surgery patients underwent: monocular/binocular and uncorrected/corrected distance visual acuity (VA) and binocular defocus curves. Binocular contrast sensitivity (CSF) and subjective halo perception were assessed with the best distance correction (CDVA), with a positive defocus of + 0.50D and with a negative defocus of −0.50D. Patient's satisfaction was evaluated with the Catquest9-SF questionnaire. Results This study included 54 eyes (28 with PanOptix and 26 with RayOne) of 27 patients. Both groups achieved corrected/uncorrected and monocular/binocular distance VA values better than 0.0 logMAR (1.0 decimal) with no statistically significant differences between them (p > 0.05 for all cases). Defocus curves showed a VA of 0.1 logMAR or better between −2.5 and + 1.0D with no differences between groups (p > 0.05 at all distances). Overall CSF values remained stable under the induced residual refractions for both groups. The halo effect remained stable for the PanOptix group but increased with myopization in the RayOne group (p = 0.02). The questionnaire showed high rates of patient's satisfaction with no differences between groups. Conclusion Both lenses showed overall good visual outcomes and offered high rates of patient's satisfaction. Moreover, in normal patients with trifocal IOLs, the combination of residual refractive errors and certain amounts of SA may increase some visual disturbances.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3