Meta-analysis of the concordance of Icare® PRO–based rebound and Goldmann applanation tonometry in glaucoma patients

Author:

Rödter Tara Helena1,Knippschild Stephanie1,Baulig Christine1,Krummenauer Frank1

Affiliation:

1. Institute for Medical Biometry and Epidemiology, Faculty of Health, Witten/Herdecke University, Witten, Germany

Abstract

Background: The Icare® PRO rebound tonometer is being promoted as a patient-friendly device for glaucoma detection and monitoring, allowing rapid and accurate intraocular pressure measurement avoiding anaesthesia. The aim of this systematic review was to examine the concordance of Icare® PRO and Goldmann applanation tonometry in glaucoma patients. Methods: The German and English literature research was carried out using PubMed and Cochrane Library between January 2010 and March 2018. Method comparison trials in a paired sample study design were identified. Search criteria were ‘Icare PRO’, ‘Rebound’, ‘Goldmann’ and ‘Applanation’. Adult patients with glaucoma of any aetiology were included. The intraindividual intraocular pressure deviation between Icare® PRO and Goldmann applanation tonometry (mm Hg) served as primary endpoint, parameterized by the reported mean differences. For each study, an asymptotic 95% confidence interval was derived. The overall intraocular pressure meta-difference (Icare® PRO-Goldmann applanation tonometry) and 95% confidence interval were estimated using the random effect model. Result: Of 147 publications, 6 studies (672 eyes) were included after reviewing. Four studies showed an intraocular pressure underestimation by the Icare® PRO, two an overestimation. The meta-difference (Icare® PRO-Goldmann applanation tonometry = −0.14 mm Hg; 95% confidence interval: (−0.43 mm Hg; 0.15 mm Hg)) indicated a non-significant, clinically irrelevant mean deviation (p = 0.335). The devices showed good agreement, but there was a strong heterogeneity between the studies (I² = 77%): two studies presented a significant difference (Icare® PRO-Goldmann applanation tonometry), however, with deviations in opposite directions. Conclusion: Although the manufacturer advertises the Icare® PRO as a ‘tonometer with superior accuracy’, the present review could neither confirm nor deny considerable agreement between Goldmann applanation tonometry and Icare® PRO in glaucomatous patients.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3