Medium-term visual and refractive outcomes in patients with pseudoexfoliation implanted with a toric or multifocal intraocular lens

Author:

Rementería-Capelo Laureano A.1,Villar Ester1,Puerto Beatriz12,López-Caballero Cristina12,Fernández-Cuenca Sara1,Contreras Inés12ORCID

Affiliation:

1. Clínica Rementería, Madrid, Spain

2. Hospital Universitario Ramón y Cajal. Instituto Ramón y Cajal de Investigaciones Sanitarias (IRYCIS), Madrid, Spain

Abstract

Purpose To report medium-term visual acuity and refractive outcomes of patients with pseudoexfoliation implanted with toric or multifocal intraocular lenses (IOLs). Methods We retrospectively reviewed patients with pseudoexfoliation who had undergone phacoemulsification between 2016 and 2020 with at least 24 months follow-up. Results Mean follow-up was 44.17 ± 14.95 months. Toric IOLs were implanted in 48 eyes: mean uncorrected LogMAR visual acuity one month after surgery was 0.03 ± 0.09, decreasing to 0.08 ± 0.11 at the last visit ( p = .01). Mean refractive cylinder was −0.12 ± 0.36 diopters one month after surgery and −0.25 ± 0.44 diopters at the last follow-up visit, p = .012. Multifocal IOLs were implanted in 42 patients: binocular uncorrected distance visual acuity was −0.02 ± 0.04 one month after surgery and 0.01 ± 0.05 at the last visit ( p = .004); near acuity was 0.01 ± 0.03 and 0.04 ± 0.06 respectively ( p = .001). In eyes with pseudoexfoliation, absolute spherical equivalent prediction error was 0.22 ± 0.20 diopters for toric and 0.21 ± 0.19 diopters for multifocal IOLs. One month after surgery 68.6% of eyes with toric IOLs and 74.2% of eyes with multifocal IOLs were within ±0.25 diopters of target spherical equivalent and 91.6% and 90.5% were within ±0.5 diopters, respectively. Spherical equivalent did not change significantly during follow-up for either group. Conclusion Prediction error in eyes with pseudoexfoliation implanted with toric or multifocal IOLs was low and similar to values reported for normal eyes. Postoperative refractive cylinder with toric IOLs was low, with little change during follow-up. Visual function in patients receiving multifocal IOLs was excellent. Therefore, the implantation of these IOLs in eyes with pseudoexfoliation does not seem to cause medium-term problems.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3