Real world outcomes of the new Tecnis Eyhance IOL

Author:

Gigon Edward1,Bouthour Walid1ORCID,Panos Georgios D2ORCID,Pajic Bojan13456,Massa Horace1ORCID

Affiliation:

1. Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland

2. Department of Ophthalmology, Queen‘s Medical Centre, Nottingham University Hospitals NHS Trust, Nottingham, UK

3. Eye Clinic Orasis, Swiss Eye Research Foundation, Reinach AG, Switzerland

4. Faculty of Medicine, University of Geneva, Geneva, Switzerland

5. Faculty of Sciences, Department of Physics, University of Novi Sad, Novi Sad, Serbia

6. Faculty of Medicine of the Military Medical Academy, University of Defense, Belgrade, Serbia

Abstract

Purpose To compare the performance of Tecnis Eyhance ICB00 with Tecnis PCB00 IOL for far, intermediate, and near vision, in patients after bilateral cataract surgery. Settings This study was done at Geneva University Hospitals. Design This is a retrospective study of 224 eyes that underwent cataract between May 2019 and June 2020. Methods Visual acuity was assessed from month 1 to 12 after surgery for distance, intermediate and near visual acuity, by the same optometrist, which was blind regarding the type of IOL. The patients answered to a quality of life questionnaire. Patients were excluded for: monocular surgery, macular disease, other IOL type, or inability to reach 20/20 visual acuity in both eyes without correction. Results One hundred and fifty-two eyes were excluded. Three groups were then analyzed: PCB00 group (38 eyes), ICB00 group (22 eyes), and mismatch group (12 eyes). Monocular visual acuities (CIVA, UNVA and CNVA, in logMAR) were higher in the ICB00 group than the PCB00 group (respectively 0.3 vs 0.4, p = 0.0033; 0.3 vs 0.4, p = 0.0408; 0.3 vs 0.4, p = 0.0039). Binocular visual acuities, CIVA and CNVA were higher in the ICB00 group than the PCB00 group (0.2 vs 0.4, p = 0.0061; 0.15 vs 0.3, p = 0.018). This mirrored the findings of the quality of life questionnaire. There was no significant difference between PCB00 and mismatch groups. Conclusions the Tecnis Eyhance was more effective for intermediate and near vision. The central defocus of the lens might help patients achieve spectacle independence and better quality of life.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3