Goldmann applanation tonometer versus ocular response analyzer for measuring intraocular pressure after congenital cataract surgery

Author:

Feizi Sepehr1,Faramarzi Amir1,Kheiri Bahareh1

Affiliation:

1. Ophthalmic Research Center, Labbafinejad Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Abstract

Purpose: To compare intraocular pressure measured using the Goldmann applanation tonometer with that measured using the ocular response analyzer after congenital cataract surgery. Methods: This study included 113 eyes of 64 patients who underwent lensectomy and vitrectomy. In all, 36 eyes remained aphakic after surgery. Intraocular lens implantation was performed at the time of surgery in 47 eyes and secondarily in 30 eyes. Corneal hysteresis, corneal resistance factor, and cornea-compensated intraocular pressure were measured. The influences of independent factors on the difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer were investigated using linear regression analyses. Agreement between the two tonometers was investigated using the Bland and Altman and 95% limits of agreement analysis. Results: Central corneal thickness, corneal hysteresis, and corneal resistance factor were 591.2 ± 53.3 µm, 10.83 ± 2.27 mmHg, and 11.36 ± 2.14 mmHg, respectively. Cornea-compensated intraocular pressure (16.75 ± 4.82 mmHg) was significantly higher than intraocular pressure measured with Goldmann applanation tonometer (14.41 ± 2.27 mmHg, p < 0.001). Central corneal thickness (p = 0.02) and corneal hysteresis (p < 0.001) were identified as the main predictors of difference between cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer readings. A 95% limits of agreement for cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was between −4.86 and 9.53 mmHg in the entire group. Cornea-compensated intraocular pressure showed the best agreement with intraocular pressure measured with Goldmann applanation tonometer in the primary pseudophakic subgroup as compared to the other subgroups. Conclusion: The Goldmann applanation tonometer and ocular response analyzer cannot be used interchangeably for measuring intraocular pressure after congenital cataract surgery. The difference between the cornea-compensated intraocular pressure and intraocular pressure measured with Goldmann applanation tonometer was primarily affected by central corneal thickness and corneal hysteresis. Among the subgroups, the primary pseudophakic subgroup had the thinnest cornea and the highest corneal hysteresis values and demonstrated the best agreement between the two tonometers.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3