Outcomes of iStent versus endocyclophotocoagulation (ECP) as adjunct to cataract surgery by phacoemulsification for glaucoma patients

Author:

Algorinees Rakan12ORCID,Almohizea Asma1,Aldalgan Hind3,Alobaida Ibrahim1,Schargel Konrad1,Aljohar Seham4

Affiliation:

1. Glaucoma Division, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia

2. Faculty of Ophthalmology, College of Medicine, University of Ha’il, Ha’il, Saudi Arabia

3. Faculty of Ophthalmology, College of Medicine, Imam Abdulrahman bin Faisal university, Al Khobar, Saudi Arabia

4. Epidemiology Section, Research Department, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia

Abstract

Purpose To compare the efficacy and safety of iStent versus Endocyclophotocoagulation (ECP) as an adjunct to cataract surgery by Phacoemulsification for treating glaucoma patients in a tertiary eye center. Methods Retrospective study of 67 eyes of 61 patients with glaucoma and cataract who underwent either phaco-ECP or phaco-iStent. Primary efficacy endpoint is the Intraocular pressure (IOP) reduction, while reduction of glaucoma medications is the secondary outcome. In addition to IOP and number of glaucoma medications; visual acuity, degree of disc cupping, safety profiles were all assessed at different intervals up to 12 months. Results A total of 40 eyes underwent phaco-ECP, and 27 eyes underwent phaco-iStent. Both groups were associated with a significant reduction in the number of glaucoma medications; however phaco-iStent group achieved slightly lower IOP levels than the phaco-ECP group. Furthermore, iStent inject had better control of IOP at the last follow-up compared to first-generation stents. Moreover; 2 or more stents significantly reduced IOP than single stent ( p = 0.009 vs. p = 0.618, respectively). Phaco-iStent achieved a better reduction in the number of glaucoma medications for primary open-angle glaucoma ( p = 0.007) compared to pseudoexfoliation glaucoma patients ( p = 0.084). Complications were seen in 12 eyes (18%), of which five eyes in phaco-ECP (7.4%) and 7 eyes in phaco-iStent (10.4%), majority were mild and treated conservatively. Conclusions Both groups had equal efficacy in reducing the IOP. However, phaco-iStent seems superior in reducing the number of glaucoma medications after 1 year of follow-up compared to phaco-ECP, particularly when 2 or more stents are used. Both groups showed an overall good safety profile.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3