The effect of tunnel length and position on postoperative corneal astigmatism: An optical coherence tomographic study

Author:

Sonmez Serap1,Karaca Cagatay1

Affiliation:

1. Department of Ophthalmology, School of Medicine, Erciyes University, Kayseri, Turkey

Abstract

Purpose: The purpose of this study is to evaluate the effects of variation in tunnel length of same-sized clear corneal phacoemulsification incisions on the generation of surgically induced astigmatism and corneal astigmatism. Methods: A total of 126 cataract patients treated in four study groups based on location and tunnel length of the clear corneal incisions (superior long, superior short, temporal long, temporal short) were reviewed. In the short tunnel groups, a 2.8 mm keratome was used with a motion parallel to the iris surface, while in the long tunnel groups, the same keratome was advanced in the corneal stroma until the mark on the keratome was reached. The surgically induced astigmatism and the corneal astigmatism were measured with corneal topography. The tunnel lengths were determined by anterior segment optical coherence tomography. Results: The tunnel lengths of the long tunnel groups were significantly longer than the short tunnel groups. The total and anterior corneal surgically induced astigmatism of the superior long group was significantly higher than the other groups. Posterior corneal surgically induced astigmatism was similar. The postoperative total and anterior corneal astigmatism values of the superior long group was significantly higher than the other groups. No difference was observed for mean change in corneal astigmatism between the groups. Conclusion: The tunnel length of a clear corneal incision is a significant determinant of surgically induced astigmatism for superior placed corneal incisions. Therefore, for superiorly positioned clear corneal incision, the incision should be rectangular with a shorter tunnel to keep the surgically induced astigmatism to a minimum. For squarer-shaped clear corneal incision, limbal-temporal incisions may be performed for astigmatic neutrality.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3