Comparative evaluation of corneal incision enlargement after intraocular lens delivery of new preloaded and manual implantation systems

Author:

Wang Lixin1,Wolfe Patricia2,Paliwal Sumit2,Chernosky Alexis2,Kohnen Thomas3ORCID

Affiliation:

1. Global Ophthalmology Development, Novartis Pharmaceuticals Corporation, Fort Worth, Texas, USA

2. Surgical Product Development, Alcon Vision, LLC, Fort Worth, Texas, USA

3. Department of Ophthalmology, Goethe University Frankfurt, Frankfurt, Germany

Abstract

Purpose: To determine whether total corneal incision enlargement after implantation of an intraocular lens with a new preloaded delivery system is comparable to a standard-of-care manual delivery system using an in vitro human cadaver eye model, despite having a smaller initial incision size. Methods: Human cadaver phakic whole eye globes were used for these studies (n = 16 per group). Each pair of eyes was randomly assigned to a new preloaded delivery system (UltraSertTM) or a manual delivery system (MONARCH® III D). The surgical procedure included creating a 2.2- and 2.4-mm corneal incision for the preloaded and manual delivery systems, respectively, measuring intraocular pressure and pre-implantation corneal incision size, delivering the intraocular lens into the anterior chamber, and measuring the post-implantation incision size. Results: The final corneal incision enlargement after intraocular lens delivery using the preloaded delivery system was 2.33 ± 0.04 mm, compared to 2.54 ± 0.05 mm after intraocular lens delivery with the manual delivery system. The mean corneal incision enlargement was comparable between the two systems, being 0.13 ± 0.04 mm using the preloaded delivery system and 0.14 ± 0.05 mm using the manual delivery system (p = 0.432). Conclusion: In a human cadaver eye model, the preloaded delivery system demonstrated an intraocular lens delivery performance on cornea incision enlargement was noninferior to the manual, standard-of-care intraocular lens delivery system despite a smaller initial incision size. Translational relevance: Smaller incision sizes for cataract surgery improve patient outcomes via faster visual and wound recovery and decreased risk of complications such as postoperative inflammation and surgically induced astigmatism.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3