Abstract

Purpose To compare the intraocular pressure (IOP) profile and the incidence of IOP spikes following selective laser trabeculoplasty (SLT) between pigmentary glaucoma (PG) and primary open-angle glaucoma (POAG). Materials and Methods Retrospective comparative study of 65 PG eyes of 51 patients matched with 65 POAG eyes of 65 patients who received SLT. Matching was done based on age, gender, glaucoma severity, pre-laser IOP, and number of medications. Post-SLT IOP spike was defined as IOP elevation ≥5mmHg, 30-45 min after the laser. Results In PG and POAG groups, the average age was 62.33 ± 9.18 and 62.58 ± 9.19 years (p = 0.95). The glaucoma severity (p = 0.708), baseline IOP (PG = 21.61 ± 1.34mmHg vs. POAG = 21.13 ± 5.09mmHg, p = 0.943), and number of topical glaucoma medications(PG = 2.34 ± 1.34 vs. POAG = 2.1 ± 1.41, p = 0.342) were comparable. More PG patients were on oral acetazolamide (PG = 26.15% vs. POAG = 1.5%, p < 0.001). Average logMAR visual acuity was significantly higher in the POAG group (0.207 ± 0.3 vs. 0.192 ± 0.37, p = 0.012). Eyes with PG received lower laser energy (POAG = 63.65 ± 22.03 mJ vs. PG = 43.71 ± 25.68 mJ, p < 0.001). IOP spikes were recorded in 5 PG eyes (7.6%) and none in the POAG group (p = 0.058). Failure rates were similar (PG = 50.7% and POAG = 43.1%, p = 0.205). In multivariable analysis, only pre-laser IOP (coefficient = 2.154 [CI: 0.765–3.543], p = 0.003) was a significant predictor of IOP change percentage after 12 months. Conclusions SLT was comparably effective in both PG and POAG. IOP spikes were observed only in the PG group, though the total laser energy was lower in this group compared with POAG.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3