New visual field indices of disharmony for early diagnosis of glaucoma, alone or associated with conventional parameters

Author:

Abreu-Gonzalez Rodrigo1,Gonzalez-Hernandez Marta2,Pena-Betancor Cristina2,Rodriguez-Esteve Paloma1,Gonzalez De La Rosa Manuel3

Affiliation:

1. Department of Ophthalmology, University Hospital of La Candelaria, Santa Cruz De Tenerife, Spain

2. Department of Ophthalmology, University Hospital of the Canary Islands, San Cristóbal de La Laguna, Spain

3. Department of Ophthalmology, University Hospital of the Canary Islands, University of La Laguna, Santa Cruz de Tenerife, Spain

Abstract

Purpose: To evaluate the specificity of new perimetric indices based on harmony, alone and in combination with structural data, for glaucoma detection. Methods: In this prospective observational cross-sectional study, one eye of 105 healthy subjects and 97 early and suspect glaucomas were sequentially included and examined with Cirrus optical coherence tomography, twice with OCULUS Smartfield perimeter (SPARK strategy) and twice with Humphrey Analyzer (24-2 SITA-Fast) at the Ophthalmology Department from the University Hospital La Candelaria. Disharmony in the visual field was evaluated including vertical threshold symmetry, threshold rank), and homogeneity (threshold standard deviation from its maximum) using the patient himself/herself as a reference. We also evaluated disharmony in combination with the mean deviation and the pattern standard deviation in a single index (mismatch) and various combinations of morphological and functional indices. Combinations used a new score based on values above certain critical cut-off levels of each index. Results: For 95% specificity, the highest sensitivities were as follows: vertical cup/disc ratio: 28.9%; SPARK threshold rank: 29.9%; and SITA-Fast threshold standard deviation: 28.9%. For the combined indices and 100% specificity, they were 5 SPARK indices mismatch: 10.3%; 5 SITA-Fast indices mismatch: 11.3%; 8 optical coherence tomography indices: 21.9%; 13 SPARK and optical coherence tomography indices: 27.8%; and 13 SITA-Fast and optical coherence tomography indices: 32.0%. Conclusion: Disharmony combined with normative value-based indices and/or optical coherence tomography indices is useful for very specific early diagnosis of glaucoma.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3