Efficacy and safety after posterior chamber Implantable Collamer Lens implantation according to preoperative anterior chamber depth: Short-term comparative study

Author:

Silva Rui1ORCID,Franqueira Nuno1,Faria-Correia Fernando12,Mendes José12,Oliveira Mariana1ORCID,Monteiro Tiago12ORCID

Affiliation:

1. Department of Ophthalmology, Hospital de Braga, Braga, Portugal

2. Life and Health Sciences Research Institute (ICVS), Escola de Medicina, Universidade do Minho, Braga, Portugal

Abstract

Purpose To compare visual, refractive, and safety outcomes of posterior chamber Implantable Collamer Lens (ICL) implantation for the correction of myopia according to the preoperative anterior chamber depth (ACD). Methods Retrospective, comparative study, patients submitted to implantation of myopic posterior-chamber phakic Implantable Collamer Lens (ICL), model V4C/V5, minimum follow-up of 12 months; two groups were created: Group 1 (ACD 2.80 to 2.99 mm) and Group 2 (ACD equal to or greater than 3.00 mm). The parameters evaluated were uncorrected and corrected visual acuity, subjective refraction, efficacy and safety index, predictability, endothelial cell density, central vault, anterior chamber angle and postoperative complications. A total of 558 eyes from 298 patients were evaluated: 111 eyes (19.9%) in group 1 and 447 eyes (80.1%) in group 2. Results At 12 months, the efficacy index was similar in both groups ( p = 0.264); the safety index was higher in group 1 ( p = 0.031); the mean central Vault was significantly lower in group 1 (212.8 vs 410.6 μm; p < 0.001). Respectively, 93 (83.8%) and 366 (84.1%) eyes were within ±0.50 D of targeted refraction. Anterior chamber angle significantly decreased during follow-up in both groups ( p < 0.001; p < 0.001). Intraocular pressure did not change significantly ( p = 0.310 and p = 0.446, respectively). There were no significant differences in endothelial cell density loss ( p = 0.278) or in the rate of complications observed ( p = 0.733). Conclusions ICL implantation is an effective and safe procedure in eyes with shallow anterior chambers, with visual and refractive results and complication rates identical to those obtained in deeper anterior chambers.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3