Atypical phacolytic glaucoma diagnosed by biometry and anterior segment optical coherence tomography (OCT) in a patient with CMV anterior uveitis

Author:

Karmiris Efthymios1ORCID,Papakonstantinou Evangelia2,Tsiripidis Konstantinos1ORCID,Stavrakas Panagiotis3ORCID,Giannakis Ioannis1,Chalkiadaki Evangelia1ORCID

Affiliation:

1. Department of Ophthalmology, 251 Hellenic Airforce General Hospital, Athens, Greece

2. First Department of Ophthalmology, National and Kapodistrian University of Athens, General Hospital “G. Gennimatas”, Athens, Greece

3. Department of Ophthalmology, School of Medicine, University of Patras, Patras, Greece

Abstract

Purpose To report a case of phacolytic glaucoma with atypical presentation in a patient which was diagnosed with biometry swept source optical coherence tomography (SS-OCT) and anterior segment spectral domain OCT (SD-OCT). Methods A 56-year-old male with a history of cytomegalovirus (CMV) chronic anterior uveitis in the right eye presented with a white cataract, minimal anterior chamber reaction and intraocular pressure (IOP) of 56 mmHg. Visual acuity was light perception. The anterior chamber was deep, without evidence of macroscopically visible capsular rupture. A surgical intervention was necessitated with the puzzle being whether to proceed with a trabeculectomy or a combined phaco-trabeculectomy. After a routine preoperative assessment with intraocular lens Master700, the disintegration of the natural lens was noticed. Anterior segment Spectralis OCT confirmed a lamellar separation of the anterior one third of the lens, resembling a poultaceous material. After an uneventful phacoemulsification, visual acuity was 6/6, IOP was well-controlled on maximum topical antiglaucoma treatment and no CMV recurrence was observed. Results The diagnosis of phacolytic glaucoma was established with the aid of current imaging OCT systems. Both OCT images were suggestive of a phacolytic nature of our case, despite the fact that the clinical presentation was not in concordance with such a typical case. In view of our findings the decision was to proceed with cataract extraction alone. Conclusion This is the first time that we image and document the phacolytic nature of a natural lens. Our patient did not have the typical clinical presentation and was differentially diagnosed with biometry SS-OCT and confirmed by anterior segment SD-OCT.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3