Endocannabinoids and cortisol in plasma, aqueous and tear samples of primary angle closure glaucoma versus controls

Author:

Angmo Dewang1ORCID,Warjri Gazella Bruce1ORCID,Gowtham L2,Velpandian Thirumurthy2,Dada Tanuj1

Affiliation:

1. Glaucoma Research Facility and Clinical Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India

2. Ocular Pharmacology, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India

Abstract

Purpose To compare the levels of endocannabinoids (EC) in plasma, aqueous humor and tears, cortisol in plasma and aqueous, in primary angle closure glaucoma (PACG) and controls, while comparing the quality of life in both groups. Methods A total of 60 patients, ≥40years of age, with a diagnosis of PACG or cataract, 30 in each group were recruited. They were subjected to a detailed ophthalmic evaluation, a WHO Quality of Life Brief Version (WHOQOL-BREF) questionnaire answering and collection of tear, aqueous and blood samples. The levels of endocannabinoids–anandamide (AEA), 2-arachidonoylglycerol (2AG) in plasma, aqueous humor and tears; cortisol in plasma and aqueous humor; and WHO-QOL score in each group were noted. Results Plasma AEA ( p = 0.01) and plasma 2-AG, ( p = 0.002) levels were significantly higher in the control group as compared to the PACG group. WHO-QOL score was better in controls ( p < 0.001). The EC were in undetectable levels in aqueous. Plasma and aqueous cortisol were significantly higher in PACG and both had the highest Area under the receiver operating characteristics (AUROC) curve value for differentiating PACG from controls. Tear 2AG and tear AEA had a moderately strong positive correlation with plasma 2-AG. Females had insignificantly higher levels of plasma and tear endocannabinoids. Conclusions Tear endocannabinoids were determined for the first time in PACG and normal with no difference between the two groups. Plasma and aqueous cortisol levels are a differentiating factor between normal and glaucoma patients with plasma endocannabinoids being remarkably higher in normals. Quality of life in glaucoma patients with high cortisol levels is poorer.

Funder

AIIMS-IRG grant

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3