We compared saturations from a paediatric central venous oximetry catheter with co-oximetry values with changes in drug infusions, intravascular blood volume and hypoxia in an animal model. Piglets (large white) were anaesthetised, intubated and mechanically ventilated. PediaSat® oximetry catheters were placed in the superior vena cava via jugular vein cut-down and in the inferior vena cava percutaneously via the femoral vein. A carotid arterial catheter was placed via cut-down for blood sampling and pressure monitoring. Anaesthesia was maintained with continuous thiopentone and supplemental morphine. Haemodynamics (heart rate, mean arterial blood, central venous pressure), fibreoptic ScvO2 (ScvO2-inferior) from inferior vena cava, fibreoptic ScvO2 (ScvO2-superior) from superior vena cava and blood gas oximetry (ScvO2-co-ox) were measured simultaneously at predetermined intervals during increasing adrenaline and sodium nitroprusside infusions and during increasing hypoxia and hypovolaemia. There was good agreement of both superior vena cava and inferior vena cava ScvO2 catheters with co-oximetry during adrenaline and sodium nitroprusside infusions. During the hypoxia study there was good agreement between the co-oximeter to ScvO2-superior catheter, but poor agreement with to the inferior vena cava catheter samples. In the hypovolaemic phase of the experiment there was good agreement between the measured co-oximetry value and ScvO2-superior catheter until the mean blood pressure reached 43 mmHg. The oximetry catheter is capable of identifying changes in ScvO2 under physiological conditions usually encountered in clinical medicine but was less accurate at the extremes of physiology and when placed in the inferior vena cava catheter especially during hypovolaemia and hypoxia.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3