Can Femoral Venous Pressure be Used as an Estimate for Standard Vesical Intra-Abdominal Pressure Measurement?

Author:

Howard A. E.1,Regli A.1,Litton E.2,Malbrain M. M.3,Palermo A-M.1,De Keulenaer B. L.1

Affiliation:

1. Intensive Care Unit, Fremantle Hospital, Fremantle, Western Australia

2. Intensive Care Unit, Fiona Stanley Hospital, Perth, Western Australia

3. Ziekenhuis Netwerk Antwerpen, ZNA Stuivenberg, Intensive Care Unit and High Care Burn Unit, Antwerp, Belgium

Abstract

Intra-abdominal hypertension (IAH) is highly prevalent in critically ill patients admitted to the intensive care unit and is associated with an increased morbidity and mortality. The present study investigated whether femoral venous pressure (EVP) can be used as a surrogate parameter for intra-abdominal pressure (IAP) measured via the bladder in IAH grade II (IAP <20 mmHg) or grade III (IAP ≥20 mmHg). This was a single-centre prospective study carried out in a tertiary adult intensive care unit. IAP was measured via the bladder with a urinary catheter with simultaneous recording of the FVP via a femoral central line. If the IAP was <20 mmHg external weight to a maximum of 10 kg was applied to the abdomen with subsequent measurements of IAP and FVP. Eleven patients were enrolled into the study. IAH (IAP >12 mmHg) was identified in five patients (42%) and abdominal compartment syndrome (ACS, IAP >20 mmHg with new onset organ failure) in two (18%) with all-cause study mortality of 18%. The mean Acute Physiology and Chronic Health Evaluation (APACHE) II score was 21 ± 5, Simplified Acute Physiology (SAPS 2) score 49 ± 8, and Sequential Organ Failure Assessment (SOFA) score 9 ± 3. At baseline the bias between IAP and FVP was 3.2 with a precision of 3.63 mmHg (limits of agreement [LA] −4.1, 10.4). At 5 kg and 10 kg, the bias was 2.5 with a precision of 3.92 mmHg (LA-5.4, 10.3) and 2.26 mmHg (LA-2.1, 7.0) respectively. A receiver operating characteristic analysis for FVP to predict IAH showed an area under the curve of 0.87 (95% confidence interval 0.74–0.94, P=0.0001). FVP cannot be recommended as a surrogate measure for IAP even at IAP values above 20 mmHg. However, an elevated FVP was a good predictor of IAH.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3