Comparison of Bioreactance Non-Invasive Cardiac Output Measurements with Cardiac Magnetic Resonance Imaging

Author:

Trinkmann F.1,Schneider C.1,Michels J. D.1,Stach K.1,Doesch C.1,Schoenberg S. O.2,Borggrefe M.3,Saur J.1,Papavassiliu T.1

Affiliation:

1. First Department of Medicine, University Medical Centre Mannheim, Mannheim, Heidelberg University, Germany

2. Institute of Clinical Radiology and Nuclear Medicine, University Medical Centre Mannheim, Mannheim, Germany

3. First Department of Medicine, University Medical Centre Mannheim, Mannheim, Germany

Abstract

Impedance cardiography measurement of cardiac output gained wide interest due to its ease of use and non-invasiveness. However, validation studies of different algorithms yielded diverging results. Bioreactance (BR) as a recent adaption differs fundamentally as the flow signal is derived from phase shifts. Our aim was to assess the accuracy and reproducibility of BR, as compared to the non-invasive gold standard-cardiac magnetic resonance imaging (CMR). We prospectively included 32 stable patients. BR was performed twice in the supine position and averaged over 30 seconds. Mean bias was 0.2 ± 1.8 l/minute (1 ± 28%, percentage error 55%) with limits of agreement ranging from −3.4 to 3.7 l/minute. Reproducibility was acceptable with a mean bias of 0.1 ± 0.9 l/minute (1 ± 14%, 27%). Low cardiac output was significantly overestimated (−1.1 ± 1.5 l/minute), while high cardiac output was underestimated (1.5 ± 1.7 l/minute), ( P=0.001), although reproducibility was unaffected. Bias and weight were moderately correlated in men (r = 0.50, P=0.02). No differences for accuracy were found in nine patients who had an arrhythmia (0.3 ± 1.4 versus 0.1 ± 2.0 l/minute, P=0.76), while clinically relevant differences were found in patients with mild aortic valve disease (1.9 ± 2.2 versus −0.3 ± 1.7 l/minute, P=0.02). Overall, BR showed insufficient agreement with CMR, overestimating low and underestimating high cardiac output states. Reproducibility was acceptable and not negatively affected by the circulatory condition. Consequently, absolute values acquired with BR should be interpreted with caution and must not be used interchangeably in clinical practice.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3