Affiliation:
1. School of Public Health and Tropical Medicine, University of Sydney, Sydney
2. Industrial Hygienist.
Abstract
A procedure for the measurement of halothane in the breathing zone of operating theatre personnel is described. This is achieved by sampling air through a U-tube containing silica gel. Concentrations found in operating theatres ranged from less than 0·1 to 8 ppm. The method can be used to evaluate exposure over a full working day.
Subject
Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine
Reference3 articles.
1. The Use of Silica Gel in Source Testing
2. Extractors for Anaesthetic Gases
3. NelsonG. O. (1971): Controlled Test Atmospheres—Principles and Techniques, Ann Arbor Science Publishers Inc., p. 184.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献