Performance of Transcutaneous Pco2 and Pulse Oximetry Monitors in Newborns and Infants After Cardiac Surgery

Author:

Carter B. G.12,Wiwczaruk D.12,Hochmann M.12,Osborne A.12,Henning R.13

Affiliation:

1. Paediatric Intensive Care Unit, Royal Children's Hospital, Melbourne, Victoria

2. , Intensive Care Technologist.

3. Staff Specialist, Paediatric Intensive Care.

Abstract

We examined the effect of core and skin temperature on the accuracy of two pulse oximeters (Nellcor Symphony and Hewlett Packard saturation module, M1020A) and a transcutaneous PCO 2 monitor (Fastrac Transcutaneous monitor) immediately after cardiac surgery in a group of newborns and infants. Seventy-nine sets of data were collected from 46 patients. Core temperatures ranged from 35.3°C to 39.4°C, skin temperatures ranged from 27.0°C to 37.4°C and core-skin temperature gradients ranged from 0.1°C to 10.1°C. Data analysis consisted of comparing the difference between transcutaneous PCO 2 and arterial PCO 2 and the differences between oxygen haemoglobin saturation measured by both pulse oximeters and oxygen haemoglobin saturation measured by co-oximeter to core temperature, skin temperature and core-skin temperature gradients. The mean differences±standard deviations and limits of agreement for transcutaneous PCO 2 and oxygen haemoglobin saturation measured by the Hewlett Packard and Nellcor pulse oximeters were 0.95±4.10 mmHg (-7.09 mmHg to 8.99 mmHg), -1.07±1.84% (-4.68% to 2.54%) and -1.23±2.23% (-5.60% to 3.14%) respectively. Analysis of correlation coefficients showed that the accuracy of the transcutaneous PCO 2 monitor and the pulse oximeters were not affected by core temperature, skin temperature or core-skin temperature gradient in the ranges encountered. We therefore conclude that these devices are acceptably accurate and suitable for use in infants when core and skin temperatures and core-skin temperature gradient are in the range normally found after cardiac surgery.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Reply to the letter;Journal of Anesthesia;2024-07-04

2. Transcutaneous PCO2 monitoring in infants hospitalized with viral bronchiolitis;European Journal of Pediatrics;2014-08-28

3. Classical Respiratory Monitoring;Pediatric and Neonatal Mechanical Ventilation;2014-04-10

4. Pulse Oximetry in Pediatric Practice;Pediatrics;2011-10-01

5. Safety of carbon dioxide insufflation for upper gastrointestinal tract endoscopic treatment of patients under deep sedation;Surgical Endoscopy;2010-01-28

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3