Ventilatory performance of AMBU® AuraGain™ and LMA® Supreme™ in laparoscopic surgery: A randomised controlled trial

Author:

Zhang Jinbin1ORCID,Drakeford Paul A1,Ng Vicky1,Seng Zhiquan1,Chua Maureen1,Tan Norman1,Mathew David1,Teoh Wendy H2

Affiliation:

1. Department of Anaesthesiology, Intensive Care and Pain Medicine, Tan Tock Seng Hospital, Singapore

2. Wendy Teoh Pte. Ltd., Private Anaesthesia Practice, Singapore.

Abstract

The Ambu® AuraGain™ (Ambu A/S, Ballerup, Denmark) is a newer phthalate-free, single-use supraglottic device with the advantage of a facility for tracheal intubation if necessary intraoperatively. We compared the oropharyngeal leak pressures and other performance variables between the AMBU AuraGain and the LMA® Supreme™ (Teleflex Medical, Athlone, Co. Westmeath, Ireland) in patients undergoing laparoscopic cholecystectomy and preperitoneoscopic inguinal herniorrhaphy with carbon dioxide insufflation under controlled ventilation. We recruited 120 American Society of Anesthesiologists physical status class I–3 patients between the ages of 21 and 80 years undergoing laparoscopic cholecystectomy or preperitoneoscopic inguinal herniorrhaphy into this single-centre randomised controlled trial. The primary outcome measure was the oropharyngeal leak pressures. Secondary outcomes included insertion parameters, ventilatory characteristics and postoperative sequelae. The AuraGain had slightly but significantly higher oropharyngeal leak pressures than the LMA Supreme (mean (standard deviation) 26.1 (6.9) versus 21.4 (4.7) cmH2O, P < 0.010). The overall insertion success of the AuraGain was comparable to the LMA Supreme (AuraGain 58/60 (96.7%); LMA Supreme 56/59 (94.9%), P = 0.679). The AuraGain was deemed more difficult to insert than the LMA Supreme, with 26/60 (43.3%) of AuraGain insertions graded easy versus 48/59 (81.4%) of LMA Supreme, P < 0.001. The mean time to insertion of the AuraGain was slightly longer than the LMA Supreme, 32.2 (10.5) versus 28.3 (12.0) s, P < 0.001. Intraoperative device failure occurred following carbon dioxide insufflation in one AuraGain and three LMA Supremes, bringing the perioperative success rate of AuraGain and LMA Supreme to 95% and 89.8%, respectively, P = 0.322. No cases of regurgitation and aspiration occurred, and minor postoperative complications were similar. The AuraGain exhibited higher oropharyngeal leak pressures than the LMA Supreme, but was slightly more difficult to insert. The higher oropharyngeal leak pressures suggest that ventilation might be less affected by high peak inspiratory pressures when using the AuraGain than the LMA Supreme.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3