Anatomical relationship between the common carotid artery and the internal jugular vein during head rotation

Author:

Miki Izumi1,Murata Satoru1,Nakazawa Ken1,Onozawa Shiro1,Mine Takahiko1,Ueda Tatsuo1,Yamaguchi Hidenori1,Yasui Daisuke1,Takeda Minako1,Kumita Shinichiro1

Affiliation:

1. Department of Radiology, Center of Advanced Medicine, Nippon Medical School, Tokyo, Japan

Abstract

This study investigated the anatomical relationship between the common carotid artery and internal jugular vein during head rotation for the effective performance of percutaneous transjugular procedures. The subjects included 30 volunteers who had never undergone internal jugular vein cannulation. In the supine position, two-dimensional ultrasonographic images of the right internal jugular vein and common carotid artery were obtained, 2 and 4 cm above the clavicle, along the lateral border of the sternal head of the sternocleidomastoid muscle. Ultrasonographic images were examined for head rotation at 0°, 15°, 30°, 45°, 60°, and 75° from the midline to the left. The percentage of overlap of the common carotid artery by the internal jugular vein and the flattening of the internal jugular vein at each head rotation position were measured and evaluated. The overlap of the common carotid artery by the internal jugular vein significantly increased at ≥45° of head rotation 2 cm above the clavicle (P < 0.01) and at ≥30° of head rotation 4 cm above the clavicle (P < 0.01), compared with that observed in the neutral position. The flattening of the internal jugular vein significantly decreased at ≥45° of head rotation 2 cm above the clavicle (P < 0.01) and at ≥30° of head rotation 4 cm above the clavicle (P < 0.01). Head rotation should be kept to <45° at 2 cm above the clavicle and <30° at 4 cm above the clavicle to decrease the risk of accidental puncture of the common carotid artery during internal jugular vein puncture. Moreover, flattening of the internal jugular vein gradually decreases during head rotation to the side.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3