Measurement of Nasalance Scores Without Touching the Philtrum for Better Comfort During Speech Assessment and Therapy: A Preliminary Study

Author:

Yang Xiaopeng1,Pratama Gradiyan Budi2,Choi Younggeun3,You Heecheon3ORCID,Tâm Nguyễn Phu'ò'c Minh4,Kim Gi-Wook56,Jo Yun-Ju6,Ko Myoung-Hwan56

Affiliation:

1. School of Artificial Intelligence and Computer Science, Jiangnan University, Wuxi, PR China

2. Department of Industrial Engineering, Bandung Institute of Technology, Bandung, Indonesia

3. Department of Industrial and Management Engineering, Pohang University of Science and Technology, Pohang, Republic of Korea

4. Department of Medicine, Chonbuk National University Medical School, Jeonju, Republic of Korea

5. Department of Physical Medicine and Rehabilitation, Chonbuk National University Medical School, Jeonju, Republic of Korea

6. Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju, Republic of Korea

Abstract

Objective: The Kay Pentax nasometer uses a separator plate that touches the philtrum of a patient to separate the nasal and oral sound energies for nasalance measurement. However, the separator plate can restrict the natural movement of the patient’s upper lip and generate unpleasant pressure on the patient’s philtrum. The present study was intended to measure nasalance scores without touching the philtrum for better comfort during speech assessment and therapy. Methods: Nasalance scores of 10 males and 10 females having no speech disorders were measured under 4 levels (0, 5, 10, and 15 mm) of the gap between the plate and the philtrum (denoted as plate-to-philtrum gap) using Nasometer II 6450 for nasal (Nasal Sentences) and oral (Zoo Passage) stimuli. Regression formulas were established to examine the relationships between nasalance score and plate-to-philtrum gap for the stimuli. To provide nasalance scores equivalent to those measured for the contact condition, compensation factors for the 5 mm plate-to-philtrum gap measurement condition were identified for the stimuli. Results: The nasalance scores were significantly different between the 4 different plate-to-philtrum gaps for the stimuli. Compensation factors for the Nasal Sentences and the Zoo Passage were identified as 1.17 and 0.71, respectively. Conclusions: The 5 mm plate-to-philtrum gap condition after multiplying the compensation factors can provide equivalent nasalance scores to the conventional contact measurement condition which may provide better comfort in speech assessment and therapy.

Funder

Fundamental Research Funds for the Central Universities

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3