Accuracy and Retention of Molding Plates Used for Infants with Cleft Lip and Palate Fabricated from Different Materials: A Cross-Sectional Clinical Study

Author:

Oday Raghad1,Abid Mushriq1ORCID

Affiliation:

1. Department of Orthodontic, College of Dentistry, University of Baghdad, Baghdad, Iraq

Abstract

Objectives The study aimed to comparatively assess the accuracy and retention of molding plates made of polyethylene terephthalate modified with glycol (PET-G) and polymethyl methacrylate (PMMA) materials, while also investigating the effect of adhesive addition on retention. Design A cross-sectional clinical study. Patients/setting The study included 30 infants diagnosed with non-syndromic cleft lip and palate (16 unilateral, 14 bilateral). Two molding plates were fabricated for each infant, and their accuracy and retention were evaluated. The data were analyzed using independent t-tests, Mann-Whitney U tests, and Wilcoxon rank tests. Main outcome measures Accuracy: The accuracy of the molding plates was assessed by measuring the virtual gap between the inner surface of the plates and their working cast using Exocad software. The accuracy was evaluated in different regions (anterior, middle, and posterior) and compared between PET-G and PMMA materials. Retention: The retention of the molding plates was measured using a digital force gauge, which recorded the force required to dislodge the plates from the infant's mouth. The retention was compared between PET-G and PMMA materials, as well as the effect of adhesive addition on retention. Overall adaptation; PET-G plates showed a significantly smaller gap (mean= 0.264 ±0.106) compared to PMMA (mean= 0.362 ±0.130). Region-specific adaptation: PET-G plates demonstrated better accuracy in all regions (means of anterior =0.246, middle =0.262, posterior =0.282 µm). Significant differences in accuracy were observed in the middle and posterior regions compared to PMMA. Retention assessment revealed that the PET-G groups (with or without adhesive) exhibited significantly higher retention compared to the PMMA groups ( P<0.01). Conclusion PET-G plates demonstrated superior accuracy and retention compared to PMMA, with a significant difference observed in both accuracy and retention. Furthermore, the addition of denture adhesive had a positive effect on retention for both materials.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3