Reduction in Peritonitis Incidence in Continuous Ambulatory Peritoneal Dialysis with a New Catheter and Implantation Technique

Author:

Moncrief Jack W.1,Popovich Robert P.2,Dasgupta Mrinal3,Costerton J. William4,Simmons Everett5,Moncrief Blain5

Affiliation:

1. Austin Diagnostic Clinic, Austin, Texas, U.S.A.

2. Austin, Bioengineering Program and the Department of Chemical Engineering, Austin, Texas, U.S.A.

3. The University of Texas, Austin, Texas, U.S.A., the University of A Iberta, Austin, Texas, U.S.A.

4. Department of Medicine, and University of Calgary, Austin, Texas, U.S.A.

5. Department of Biological Sciences, Calgary, Alberta, Canada, and the Moncrief-Popovich Research Institute, Austin, Texas, U.S.A.

Abstract

Recurrent episodes of peritonitis with the same organism cultured at the catheter exit site suggest that early tunnel colonization is associated with a transfer of these organisms through the catheter tunnel directly from the skin Into the peritoneal cavity. In this instance the catheter has failed In Its fundamentel design to establish and maintain a bacteriological berrier. A three-part study was conducted using the Moncrlef-Popovich catheter and Implantation technique. The first part of the study Included 59 patients who used standard spike exchange systems with this new catheter and implantation technique. A reduction in the incidence of peritonitis occurred in the continuous ambulatory peritoneal dialysis (CAPO) program at the Austin Olagnostic Clinic. The previous peritonitis incidence was 1 every 9 patient-months. This study had 1 every 29 patient-months with 530 patient months of experience. The second part of the study had 79 patients. All except 11 used disconnect exchange systems. There was a total of 482 patient-months of experience with 1 episode every 27 patient-months. Those using the disconnect systems (86%) had 1 episode every 32 petient-months. The third part of the study Included microscopic studies of 12 excised catheters. Three were known to be contaminated. The examiners identified those catheters that were free or nearly free of biofilm on the catheter segment between the two cuffs. It Is concluded that biofilm analysis and reduction In peritonitis Incidence supports the theory that the new catheter and implantation technique form an Improved becterlologlcal barrier In the access for peritoneal dialysis.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3