The Standard Peritoneal Permeability Analysis in the Rabbit: A Longitudinal Model for Peritoneal Dialysis

Author:

Zweers Machteld M.1,Douma Caroline E.1,De Waart Dirk R.2,Van Der Wardt Anton B.3,Ho-Dac-Pannekeet Marja M.1,Krediet Raymond T.1,Struijk Dirk G.14

Affiliation:

1. Departments of Nephrology Utrecht, The Netherlands

2. Clinical Chemistry, Utrecht, The Netherlands

3. Academic Medical Center Amsterdam; Communal Animal Institute Amsterdam, Utrecht, The Netherlands

4. Foundation for Home Dialysis Midden-West Nederland, Utrecht, The Netherlands

Abstract

Objective The development of an experimental peritoneal dialysis (PD) model in rabbits to investigate peritoneal transport characteristics during a longitudinal follow-up and to assess normal values of these peritoneal transport parameters. Design Peritoneal transport parameters were determined in conscious, unrestrained rabbits by standard peritoneal permeability analysis adjusted for rabbits (SPAR). In this test a 1-hour dwell with 3.86% glucose dialysate is used. Dextran 70 (1 g/L) was added to the dialysate to allow calculation of fluid kinetics. Dialysate samples were taken before, 10, and 40 minutes after instillation and at the end of the dwell. Blood was drawn at the end of the dwell. Experimental Animals Eighteen female New Zealand White rabbits (2565 g) were included for catheter implantation. SPARs were performed in 15 animals; the other 3 were excluded due to complications. Main Outcome The mass transfer area coefficients (MTACs) of the low molecular weight solutes urea (MTACurea) and creatinine (MTACcr) were calculated. The clearances of albumin (Clalb) and IgG (ClIgG), glucose absorption, and fluid transport were computed. Coefficients of intraindividual variation (Vc) were calculated for these parameters. Results The main complications were catheter obstruction and/or dislocation. Five rabbits underwent uncomplicated PD during a 4-week period. Fifteen SPARs in 15 stable rabbits were performed and analyzed to obtain normal values. Means and standard deviations of the transport parameters were as follows: MTACurea 2.24 ± 0.57 mL/min, MTACcr 1.61 ± 0.30 mL/min, Clalb 52.9 ± 17.2 μL/min, ClIgG 44.5 ± 22.9 μL/min. The transcapillary ultrafiltration rate was 0.66 ± 0.13 mL/min and the lymphatic absorption rate 0.47 ± 0.26 mL/min. The parameters of solute transport were upscaled to those in humans using two different methods. MTACs of low molecular weight solutes in rabbits and patients were of the same order of magnitude, but the clearance of albumin was approximately four times higher in rabbits than in patients, and that of IgG eight times. In all rabbits sieving of sodium was observed. The dialysate/plasma (D/P) of sodium decreased to a minimum at 40 min ( p < 0.003 vs the initial value), followed by a rise to 60 min. The minimal value was 0.884 ± 0.002. The coefficients of variation calculated on 7 rabbits that underwent two or more SPARs were similar to those assessed from the patient data. This indicates stability of the model and reproducibility of the SPAR. Conclusion The conscious rabbit model for PD can be used for repeated studies on peritoneal transport.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Animal Models for Peritoneal Dialysis Research;Nolph and Gokal's Textbook of Peritoneal Dialysis;2023

2. Experimental systems to study the origin of the myofibroblast in peritoneal fibrosis;Kidney Research and Clinical Practice;2016-09

3. The role of the lymphatic system in rabbit models for cancer metastasis research: a perspective from comparative anatomy;Okajimas Folia Anatomica Japonica;2014

4. Ultrafiltration Characteristics of Glucose Polymers with Low Polydispersity;Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis;2013-03

5. Hyperpressure Intraperitoneal Fluid Administration for Control of Bleeding after Liver Injury;Journal of Surgical Research;2012-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3