Diagnostic capability of ultrasound in peritoneal catheter malfunction compared to videolaparoscopy

Author:

Zeiler Matthias1ORCID,Federico Antonio1,Lentini Paolo2,Dell’Aquila Roberto2,Santarelli Stefano1,Granata Antonio3,

Affiliation:

1. Nephrology and Dialysis Unit, ‘Carlo Urbani’ Hospital, Jesi, Italy

2. Nephrology and Dialysis Unit, ‘San Bassiano’ Hospital, Bassano del Grappa, Italy

3. Nephrology and Dialysis Unit, ‘Cannizzaro’ Hospital, Catania, Italy

Abstract

Background: The approach to peritoneal catheter malfunction consists usually in a diagnostic and therapeutic sequence of laxative prescription, abdominal radiography, brushing of the catheter, guide-wire manipulation or fluoroscopy and in the end of a videolaparoscopy (VLS) rescue intervention. Ultrasound (US) is able to find out major causes of peritoneal catheter malfunction, however without a clearly defined diagnostic value. The aim of the study was to validate the diagnostic capability of US in catheter malfunction compared to the diagnostic reference of VLS. Methods: US scans of the subcutaneous and intraperitoneal segment of the catheter were performed prior to a VLS intervention in 40 adult patients presenting persistent catheter malfunction within a prospective multicentre study. Laxative prescription and brushing of the catheter lumen were undertaken prior to US scan. US diagnosis was compared to the corresponding at VLS, kappa coefficient calculated and the causes of mismatch analysed. Results: In US, causes of persistent malfunction were catheter dislocation combined with omental wrapping in 21 cases, omental wrapping without dislocation in 11 cases, dislocation only in 4 cases, adherences to non-omental structures in 3 cases and entrapment in the lateral inguinal fossa in 1 case. The US diagnosis corresponded to the respective at VLS in 36 of 40 cases, resulting in a kappa coefficient of 0.89 (95% CI: 0.78–1.00). The discrepancies were due to improper visualization of the catheter between omentum and intestinal loops, resulting in an erroneous US diagnosis of omental wrapping. Conclusions: This study suggests that US might have a pivotal role in the diagnostic approach to peritoneal catheter dysfunction.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3