Kinetic Analysis of Peritoneal Fluid and Solute Transport with Combination of Glucose and Icodextrin as Osmotic Agents

Author:

Galach Magda1,Werynski Andrzej1,Waniewski Jacek1,Freida Philippe2,Lindholm Bengt3

Affiliation:

1. Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland

2. Department of Nephrology, Louis Pasteur District Hospital, Cherbourg, France

3. Divisions of Baxter Novum and Renal Medicine, Department of Clinical Science, Intervention and Technology, Karolinska University Hospital Huddinge, Karolinska Institutet, Stockholm, Sweden

Abstract

Background Controlling extracellular volume and plasma sodium concentration are two crucial objectives of dialysis therapy, as inadequate sodium and fluid removal by dialysis may result in extracellular volume overload, hypertension, and increased cardiovascular morbidity and mortality in end-stage renal disease patients. A new concept to enhance sodium and fluid removal during peritoneal dialysis (PD) is the use of dialysis solutions with two different osmotic agents. Aim To investigate and compare, with the help of mathematical modeling and computer simulations, fluid and solute transport during PD with conventional dialysis fluids (3.86% glucose and 7.5% icodextrin; both with standard sodium concentration) and a new combination fluid with both icodextrin and glucose (CIG; 2.6% glucose/6.8% icodextrin; low sodium concentration). In particular, this paper is devoted to improving mathematical modeling based on critical appraisal of the ability of the original three-pore model to reproduce clinical data and check its validity across different types of osmotic agents. Methods Theoretical investigations of possible causes of the improved fluid and sodium removal during PD with the combination solution (CIG) were carried out using the three-pore model. The results of computer simulations were compared with clinical data from dwell studies in 7 PD patients. To fit the model to the low net ultrafiltration (366 ± 234 mL) obtained after a 4-hour dwell with 3.86% glucose, some of the original parameters proposed in the three-pore model (Rippe & Levin. Kidney Int 2000; 57:2546-56) had to be modified. In particular, the aquaporin-mediated fractional contribution to hydraulic permeability was decreased by 25% and small pore radius increased by 18%. Results The simulations described well clinical data that showed a dramatic increase in ultrafiltration and sodium removal with the CIG fluid in comparison with the two other dialysis fluids. However, to adapt the three-pore model to the selected group of PD patients (fast transporters with small ultrafiltration capacity on average), the peritoneal pore structure had to be modified. As the mathematical model was capable of reproducing the clinical data, this shows that the enhanced ultrafiltration with the combination fluid is caused by the additive effect of the two different osmotic agents and not by a specific impact of the new dialysis fluid on the transport characteristics of the peritoneum.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3