Comparison of the Radioiodinated Serum Albumin (RISA) Dilution Technique with Direct Volumetric Measurements in Animal Models of Peritoneal Dialysis

Author:

Biesen Van Wim1,Devriese An S.1,Carlsson Ola2,Landschoot Van Mike1,Dheuvaert Tomy1,Lameire Norbert H.1

Affiliation:

1. Department of Internal Medicine, Renal Division, University Hospital Gent, Gent

2. Department of Nephrology and Physiology, University Lund, Lund, Belgium

Abstract

Background Rat models of peritoneal dialysis (PD) are useful for studying the physiology of peritoneal transport and evaluating new osmotic agents. Intraperitoneal (IP) solute concentrations and their evolution over time are easy to measure, but IP volume (IPV) is not. Direct volumetric measurements are the “gold standard,” but they are expensive and do not allow for repetitive measurements in the same animal. The indicator dilution technique is therefore used as an alternative. However, that technique is based on assumptions that are not always valid. The present study compares direct volume measurement with the indicator dilution technique [radioiodinated serum albumin (RISA)] to determine the IPV over time curves in a rat model of PD. Methods In series 1, 17 Sprague–Dawley rats were instilled IP with 25 mL 1.36% glucose dialysate through a Teflon catheter. In 9 animals, 0.35 mL dialysate was sampled and discarded at time points 0, 3, 15, 30, 60, 180, and 240 minutes. In the other 8 animals, no sampling was performed. At 240 minutes, all 12 animals were humanely killed, and direct volumetric measurements of IPV were performed. In series 2, rats were instilled IP with 25 mL 1.36% glucose dialysate containing 18.5 kBq 131I RISA. In 9 animals, dialysate was sampled at 0, 3, 15, 30, 60, 90, 120, 180, and 240 minutes for the construction of the RISA concentration-over-time curve, and to calculate the elimination constant Ke. At 30, 60, 180, and 240 minutes, dialysate was sampled in 6 different animals (total n = 24) to calculate IPV using the RISA dilution technique. Immediately afterward, the animals were humanely killed, and direct volumetric measurements of IPV were performed. Results In series 1, after 240 minutes’ dwell time, the IPV was lower in the sampled animals as compared with the non sampled animals (27.11 ± 1.85 mL vs 30.75 ± 0.59 mL, p = 0.001). In series 2, the evolution of RISA activity in the dialysate over time was described by piecewise linear regression, yielding 3288 – 8.2T counts (cts) for T < 52.72 minutes and 2973 – 1.99T counts for T > 52.72 minutes. The IPV was better predicted with a Ke that took into account the disappearance of RISA by sampling than with a Ke that took into account disappearance of RISA only by absorption. Conclusions If indicator dilution techniques are used to measure IPV, attention must be paid to the disappearance of the osmotic agent and the marker by multiple sampling. The best way to meet that goal is to use micropipettes to avoid large sample volumes.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Animal Models for Peritoneal Dialysis Research;Nolph and Gokal's Textbook of Peritoneal Dialysis;2023

2. A review of rodent models of peritoneal dialysis and its complications;International Urology and Nephrology;2014-11-26

3. Quantification of osmotic water transport in vivo using fluorescent albumin;American Journal of Physiology-Renal Physiology;2014-10-15

4. How to Assess Transport in Animals?;Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis;2009-02

5. Animal Models for Peritoneal Dialysis Research;Nolph and Gokal’s Textbook of Peritoneal Dialysis;2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3