Influence of Plasticizer-Free CAPD Bags and Tubings on Serum, Urine, and Dialysate Levels of Phthalic Acid Esters in CAPD Patients

Author:

Mettang Thomas1,Pauli–Magnus Christiane1,Alscher Dominik Mark1,Kirchgessner Judith2,Wodarz Roman3,Rettenmeier Albert W.4,Kuhlmann Ulrich1

Affiliation:

1. Division of Nephrology, Department of Internal Medicine, Robert Bosch Hospital, Stuttgart

2. Fresenius Medical Care Deutschland, Bad Homburg

3. Department of Occupational and Social Medicine, University of Tuebingen, Tuebingen

4. Department of Hygiene and Occupational Medicine, University of Essen, Essen, Germany

Abstract

Objectives To evaluate the impact of a plasticizer-free device on exposure to di-(2-ethylhexyl) phthalate (DEHP) and its major metabolites in patients on continuous ambulatory peritoneal dialysis (CAPD). DEHP is the most commonly used plasticizer in polyvinyl chloride (PVC) products; it is added to CAPD bags in order to improve the flexibility of the material. Since DEHP leaches out of the plastic matrix, patients on CAPD are exposed to considerable amounts of DEHP and its metabolites. Design A prospective cross-over study. Setting Department of nephrology in a teaching hospital. Participants Six patients (4 female, 2 male) stable on peritoneal dialysis (PD) for at least 6 months. Interventions Patients were switched from a plasticizer-containing PVC CAPD system (A.N.D.Y. Plus, Fresenius Medical Care, Bad Homburg, Germany) to a polyolefine-made plasticizer-free system (stay-safe, Fresenius). Main Outcome Measures Prior to and 42 days after the switch, 24-hour effluent dialysate and urine collections were performed and 10 mL blood was drawn. Concentrations of DEHP, mono-(2-ethylhexyl) phthalate (MEHP), phthalic acid (PA), and 2-ethylhexanol (2-EH) in urine, dialysate, and serum were determined using gas chromatography/mass spectrometry. Results Complete data were obtained from 5 patients. Serum levels of PA decreased significantly during the study period (0.137 ± 0.078 mg/L vs 0.124 ± 0.049 mg/L, p = 0.04), and the respective levels of DEHP decreased insignificantly (0.097 ± 0.076 mg/L vs 0.069 ± 0.046 mg/L, p = 0.07), whereas the concentrations of MEHP and 2-EH remained unchanged. Urine concentrations of PA were high (0.81 ± 0.69 mg/L) but did not change substantially (0.70 ± 0.50 mg/L). Effluent dialysate concentrations of MEHP and PA decreased significantly (0.0176 ± 0.004 mg/L vs 0.0040 ± 0.0007 mg/L, p = 0.043 and 0.158 ± 0.056 mg/L vs 0.111 ± 0.051 mg/L, p = 0.043, respectively). Conclusions Although PD patients seem to be exposed to other sources of phthalates in addition to dialysis, use of plasticizer-free devices may help to reduce potentially immunosuppressive exposure to phthalate esters.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Effects of Behavioral, Clinical, and Policy Interventions in Reducing Human Exposure to Bisphenols and Phthalates: A Scoping Review;Environmental Health Perspectives;2024-03

2. Endocrine disruptors in dialysis therapies: A literature review;Environment International;2023-08

3. Advanced hemodialysis equipment for more eco-friendly dialysis;International Urology and Nephrology;2021-09-04

4. Non-polyvinyl chloride peritoneal dialysis sets: A double-edged sword?;Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis;2021-04-07

5. Technical Aspects and Prescription of Peritoneal Dialysis in Children;Pediatric Dialysis;2021