Affiliation:
1. Division of Nephrology, Department of Internal Medicine, Robert Bosch Hospital, Stuttgart
2. Fresenius Medical Care Deutschland, Bad Homburg
3. Department of Occupational and Social Medicine, University of Tuebingen, Tuebingen
4. Department of Hygiene and Occupational Medicine, University of Essen, Essen, Germany
Abstract
Objectives To evaluate the impact of a plasticizer-free device on exposure to di-(2-ethylhexyl) phthalate (DEHP) and its major metabolites in patients on continuous ambulatory peritoneal dialysis (CAPD). DEHP is the most commonly used plasticizer in polyvinyl chloride (PVC) products; it is added to CAPD bags in order to improve the flexibility of the material. Since DEHP leaches out of the plastic matrix, patients on CAPD are exposed to considerable amounts of DEHP and its metabolites. Design A prospective cross-over study. Setting Department of nephrology in a teaching hospital. Participants Six patients (4 female, 2 male) stable on peritoneal dialysis (PD) for at least 6 months. Interventions Patients were switched from a plasticizer-containing PVC CAPD system (A.N.D.Y. Plus, Fresenius Medical Care, Bad Homburg, Germany) to a polyolefine-made plasticizer-free system (stay-safe, Fresenius). Main Outcome Measures Prior to and 42 days after the switch, 24-hour effluent dialysate and urine collections were performed and 10 mL blood was drawn. Concentrations of DEHP, mono-(2-ethylhexyl) phthalate (MEHP), phthalic acid (PA), and 2-ethylhexanol (2-EH) in urine, dialysate, and serum were determined using gas chromatography/mass spectrometry. Results Complete data were obtained from 5 patients. Serum levels of PA decreased significantly during the study period (0.137 ± 0.078 mg/L vs 0.124 ± 0.049 mg/L, p = 0.04), and the respective levels of DEHP decreased insignificantly (0.097 ± 0.076 mg/L vs 0.069 ± 0.046 mg/L, p = 0.07), whereas the concentrations of MEHP and 2-EH remained unchanged. Urine concentrations of PA were high (0.81 ± 0.69 mg/L) but did not change substantially (0.70 ± 0.50 mg/L). Effluent dialysate concentrations of MEHP and PA decreased significantly (0.0176 ± 0.004 mg/L vs 0.0040 ± 0.0007 mg/L, p = 0.043 and 0.158 ± 0.056 mg/L vs 0.111 ± 0.051 mg/L, p = 0.043, respectively). Conclusions Although PD patients seem to be exposed to other sources of phthalates in addition to dialysis, use of plasticizer-free devices may help to reduce potentially immunosuppressive exposure to phthalate esters.
Subject
Nephrology,General Medicine
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献