Intensive recreational athletes in the prospective multinational ICD Sports Safety Registry: Results from the European cohort

Author:

Heidbuchel Hein1,Willems Rik2,Jordaens Luc3,Olshansky Brian4,Carre Francois5,Lozano Ignacio F6,Wilhelm Matthias7,Müssigbrodt Andreas8,Huybrechts Wim1,Morgan John9,Anfinsen Ole-Gunnar10,Prior David11,Mont Lluis12,Mairesse Georges H13,Boveda Serge14,Duru Firat15,Kautzner Josef16,Viskin Sami17,Geelen Peter18,Cygankiewicz Iwona19,Hoffmann Ellen20,Vandenberghe Katleen2,Cannom David21,Lampert Rachel22

Affiliation:

1. Antwerp University & University Hospital, Belgium

2. University of Leuven, Belgium

3. Erasmus Medical Centre, Rotterdam, The Netherlands

4. Mercy Heart and Vascular Institute, Mason City, USA

5. University Hospital of Rennes, France

6. University Hospital Puerta de Hierro Majadahonda, Madrid, Spain

7. University of Bern, Switzerland

8. University of Leipzig, Heart Centre, Germany

9. University of Southampton, UK

10. Oslo University Hospital Rikshospitalet, Norway

11. St Vincent's Hospital, Melbourne, Australia

12. Hospital Clínic, Universitat de Barcelona, Spain

13. Cliniques du Sud-Luxembourg, Arlon, Belgium

14. Cardiology – Arrhythmias Management Department, Clinique Pasteur, Toulouse, France

15. University Heart Centre, Zurich, Switzerland

16. Institute for Clinical and Experimental Medicine, Prague, Czech Republic

17. Tel Aviv Sourasky Medical Center and Sackler School of Medicine, Tel Aviv University, Israel

18. Cardiovascular Centre, OLV Hospital, Aalst, Belgium

19. Department of Electrocardiology, Medical University of Lodz, Poland

20. Heart Centre Munich-Bogenhausen, Munich Municipal Hospital Group, Germany

21. Cedars-Sinai Medical Center, Los Angeles, USA

22. Yale University, New Haven, USA

Abstract

Background In the ICD Sports Safety Registry, death, arrhythmia- or shock-related physical injury did not occur in athletes who continue competitive sports after implantable cardioverter-defibrillator (ICD) implantation. However, data from non-competitive ICD recipients is lacking. This report describes arrhythmic events and lead performance in intensive recreational athletes with ICDs enrolled in the European recreational arm of the Registry, and compares their outcome with those of the competitive athletes in the Registry. Methods The Registry recruited 317 competitive athletes ≥ 18 years old, receiving an ICD for primary or secondary prevention (234 US; 83 non-US). In Europe, Israel and Australia only, an additional cohort of 80 ‘auto-competitive’ recreational athletes was also included, engaged in intense physical activity on a regular basis (≥2×/week and/or ≥ 2 h/week) with the explicit aim to improve their physical performance limits. Athletes were followed for a median of 44 and 49 months, respectively. ICD shock data and clinical outcomes were adjudicated by three electrophysiologists. Results Compared with competitive athletes, recreational athletes were older (median 44 vs. 37 years; p = 0.0004), more frequently men (79% vs. 68%; p = 0.06), with less idiopathic ventricular fibrillation or catecholaminergic polymorphic ventricular tachycardia (1.3% vs. 15.4%), less congenital heart disease (1.3% vs. 6.9%) and more arrhythmogenic right ventricular cardiomyopathy (23.8% vs. 13.6%) ( p < 0.001). They more often had a prophylactic ICD implant (51.4% vs. 26.9%; p < 0.0001) or were given a beta-blocker (95% vs. 65%; p < 0.0001). Left ventricular ejection fraction, ICD rate cut-off and time from implant were similar. Recreational athletes performed fewer hours of sports per week (median 4.5 vs. 6 h; p = 0.0004) and fewer participated in sports with burst-performances ( vs. endurance) as their main sports: 4% vs. 65% ( p < 0.0001). None of the athletes in either group died, required external resuscitation or was injured due to arrhythmia or shock. Freedom from definite or probable lead malfunction was similar (5-year 97% vs. 96%; 10-year 93% vs. 91%). Recreational athletes received fewer total shocks (13.8% vs. 26.5%, p = 0.01) due to fewer inappropriate shocks (2.5% vs. 12%; p = 0.01). The proportion receiving appropriate shocks was similar (12.5% vs. 15.5%, p = 0.51). Recreational athletes received fewer total (6.3% vs. 20.2%; p = 0.003), appropriate (3.8% vs. 11.4%; p = 0.06) and inappropriate (2.5% vs. 9.5%; p = 0.04) shocks during physical activity. Ventricular tachycardia/fibrillation storms during physical activity occurred in 0/80 recreational vs. 7/317 competitive athletes. Appropriate shocks during physical activity were related to underlying disease ( p = 0.004) and competitive versus recreational sports ( p = 0.004), but there was no relation with age, gender, type of indication, beta-blocker use or burst/endurance sports. The proportion of athletes who stopped sports due to shocks was similar (3.8% vs. 7.5%, p = 0.32). Conclusions Participants in recreational sports had less frequent appropriate and inappropriate shocks during physical activity than participants in competitive sports. Shocks did not cause death or injury. Recreational athletes with ICDs can engage in sports without severe adverse outcomes unless other reasons preclude continuation.

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Epidemiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3