Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography

Author:

Silva Lopes Bruno1ORCID,Craveiro Nuno2,Firmino-Machado João3ORCID,Ribeiro Pedro4,Castelo-Branco Miguel5

Affiliation:

1. Tondela-Viseu Hospital Center, Physical and Rehabilitation Medicine Department, Avenida Rei D. Duarte, Viseu, 3504-509, Portugal

2. Lusitana Family Health Unit, Viseu, Portugal

3. Porto University, Porto, Portugal

4. Tondela-Viseu Hospital Center, Viseu, Portugal

5. University of Beira Interior, Covilhã, Portugal

Abstract

Background: Impedance cardiography is a reliable, well-tolerated, and non-invasive method used to obtain hemodynamic measurements and could potentially be useful in heart failure (HF) diagnosis, hemodynamic monitoring of critically ill patients, and help in the choice of antihypertensive therapy. The objective of this study was to determine the differences between hemodynamic parameters in a study population of hypertensive patients with and without HF, using impedance cardiography. Methods: A case-control study was designed and named the TARGET study. Participants were enrolled in two study groups: control group C, hypertensive patients without HF and the HF group, hypertensive patients with HF. A descriptive analysis was carried out to characterize the sample and differences in continuous variables were tested for statistical significance by independent sample t test. Results: The study included 102 hypertensive outpatients. The control group consisted of 77 individuals (58.4% males; mean age 63.9 ± 12.5 years old) and the HF group consisted of 25 individuals (44.0% males; mean age 74.2 ± 8.7 years old). The mean Cardiac Index (CI) was 2.70 ± 1.02 L.min.m−2 (2.89 ± 1.04 versus 2.12 ± 0.70; p < 0.001), mean Stroke Index (SI) was 35.5 ± 14.7 mL.m−2 (37.7 ± 15.2 versus 28.5 ± 10.8; p = 0.006), mean Ejection Phase Contractility Index (EPCI) was 33.7 ± 12.7 1000 s−2 (35.8 ± 13.1 versus 27.2 ± 9.2; p = 0.003), mean Inotropic State Index (ISI) was 74.3 ± 28.2 100 s−2 (78.8 ± 28.9 versus 60.6 ± 20.7; p = 0.005), and mean Left Stroke Work Index (LSWI) was 51.3 ± 23.1 g.min.m−2 (55.4 ± 23.5 versus 38.9 ± 16.6; p = 0.002). Conclusions: In this study, hypertensive patients with HF had significantly lower values of blood flow parameters, contractility, and left work indices compared with hypertensive patients without HF. These differences reflected the incorrect hemodynamic pattern (mostly hypodynamic) of these patients. Impedance cardiography (ICG) seems to be an adequate method to reflect these differences.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3