Quantification of hematoma and perihematomal edema volumes in intracerebral hemorrhage study: Design considerations in an artificial intelligence validation (QUANTUM) study

Author:

Ironside Natasha1,Patrie James2,Ng Sherman3,Ding Dale4,Rizvi Tanvir5,Kumar Jeyan S1,Mastorakos Panagiotis1,Hussein Mohamed Z5,Naamani Kareem El6,Abbas Rawad6,Harrison Snyder M7ORCID,Zhuang Yan8,Kearns Kathryn N1,Doan Kevin T1,Shabo Leah M1ORCID,Marfatiah Saurabh9,Roh David10,Lignelli-Dipple Angela9,Claassen Jan10,Worrall Bradford B211,Johnston Karen C211,Jabbour Pascal6,Park Min S1,Sander Connolly E12,Mukherjee Sugoto5,Southerland Andrew M211,Chen Ching-Jen13ORCID

Affiliation:

1. Department of Neurological Surgery, University of Virginia School of Medicine, Charlottesville, VA, USA

2. Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, VA, USA

3. Department of Software Engineering, Microsoft Corporation, Redmond, WA, USA

4. Department of Neurosurgery, University of Louisville School of Medicine, Louisville, KY, USA

5. Department of Radiology and Medical Imaging, University of Virginia School of Medicine, Charlottesville, VA, USA

6. Department of Neurosurgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA

7. Department of Neurosurgery, Tufts Medical Center, Boston, MA, USA

8. Department of Biomedical Engineering and Electrical and Computer Engineering, University of Virginia, Charlottesville, VA, USA

9. Department of Radiology, Columbia University School of Medicine, New York, NY, USA

10. Department of Neurology, Columbia University School of Medicine, New York, NY, USA

11. Department of Neurology, University of Virginia School of Medicine, Charlottesville, VA, USA

12. Department of Neurosurgery, Columbia University School of Medicine, New York, NY, USA

13. Department of Neurosurgery, The University of Texas Health Science Center, Houston, TX, USA

Abstract

Background: Hematoma and perihematomal edema volumes are important radiographic markers in spontaneous intracerebral hemorrhage. Accurate, reliable, and efficient quantification of these volumes will be paramount to their utility as measures of treatment effect in future clinical studies. Both manual and semi-automated quantification methods of hematoma and perihematomal edema volumetry are time-consuming and susceptible to inter-rater variability. Efforts are now underway to develop a fully automated algorithm that can replace them. A (QUANTUM) study to establish inter-quantification method measurement equivalency, which deviates from the traditional use of measures of agreement and a comparison hypothesis testing paradigm to indirectly infer quantification method measurement equivalence, is described in this article. The Quantification of Hematoma and Perihematomal Edema Volumes in Intracerebral Hemorrhage study aims to determine whether a fully automated quantification method and a semi-automated quantification method for quantification of hematoma and perihematomal edema volumes are equivalent to the hematoma and perihematomal edema volumes of the manual quantification method. Methods/Design: Hematoma and perihematomal edema volumes of supratentorial intracerebral hemorrhage on 252 computed tomography scans will be prospectively quantified in random order by six raters using the fully automated, semi-automated, and manual quantification methods. Primary outcome measures for hematoma and perihematomal edema volumes will be quantified via computed tomography scan on admission (<24 h from symptom onset) and on day 3 (72 ± 12 h from symptom onset), respectively. Equivalence hypothesis testing will be conducted to determine if the hematoma and perihematomal edema volume measurements of the fully automated and semi-automated quantification methods are within 7.5% of the hematoma and perihematomal edema volume measurements of the manual quantification reference method. Discussion: By allowing direct equivalence hypothesis testing, the Quantification of Hematoma and Perihematomal Edema Volumes in Intracerebral Hemorrhage study offers advantages over radiology validation studies which utilize measures of agreement to indirectly infer measurement equivalence and studies which mistakenly try to infer measurement equivalence based on the failure of a comparison two-sided null hypothesis test to reach the significance level for rejection. The equivalence hypothesis testing paradigm applied to artificial intelligence application validation is relatively uncharted and warrants further investigation. The challenges encountered in the design of this study may influence future studies seeking to translate artificial intelligence medical technology into clinical practice.

Publisher

SAGE Publications

Subject

Pharmacology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3