Biocompatibility of Poly (DL-Lactide-co-Glycolide) Microspheres Implanted into the Brain

Author:

Emerich Dwaine F.1,Tracy Mark A.1,Ward Kevin L.1,Figueiredo Maria1,Qian Rulin1,Henschel Carroll1,Bartus Raymond T.1

Affiliation:

1. Alkermes, Inc., 64 Sidney Street, Cambridge, MA 02139

Abstract

The delivery of therapeutic molecules to the brain has been limited in part due to the presence of the blood–brain barrier. One potential solution is the implantation of biodegradable polymers with sustained release of drugs. Poly (DL-lactide-co-glycolide) (PLG) is a bioerodible polymer with a long and successful history of use as a suture material. More recently, PLG has been investigated for localized and sustained delivery of molecules into both peripheral sites and the brain. Despite its well-defined safety profile for parenteral applications, little information exists concerning the safety of PLG when implanted into the brain. To further characterize the biocompatibility of PLG in the brain, we examined the gliotic response following implants of PLG into the brains of rats. As a control, each animal received an injection of the suspension medium into the contralateral hemisphere. Following implantation, PLG was well tolerated. GFAP-positive astrocytes were observed throughout the cerebral cortex and striatum on both the implanted and control sides, with the reaction being greatest within the heavily myelinated fiber tracts of the corpus callosum. Quantitative analyses revealed that this reaction occurred within 1 h postsurgery, reached its peak at 1 week following surgery, and then decreased markedly by 1 month postsurgery. A minimal gliotic reaction was still present 1 year postsurgery but was localized to the needle tract. No differences in GFAP reactivity were seen between the polymer-implanted and control sides at any time point. Histological analysis determined that the majority of the PLG disappeared between 1 and 4 weeks. A set of parallel studies in which PLG samples were retrieved from the brain at various time points corroborated these findings and determined that the majority of PLG degraded within 2 weeks following implantation. Together, these results demonstrate that PLG is well tolerated following implantation into the CNS and that the astrocytic response to PLG is largely a consequence of the mechanical trauma that occurs during surgery. The biocompatibility of PLG implanted into the CNS provides further support for its use in a wide range of new therapeutic applications for sustained and localized drug delivery to the brain.

Publisher

SAGE Publications

Subject

Transplantation,Cell Biology,Biomedical Engineering

Cited by 73 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Polymer and its nanocomposites as an antimicrobial coating for medical devices and implants;Next-Generation Antimicrobial Nanocoatings for Medical Devices and Implants;2024

2. Nano‐Engineering in Traumatic Brain Injury;Impact of Engineered Nanomaterials in Genomics and Epigenomics;2023-05-15

3. Nanotherapeutic treatment of the invasive glioblastoma tumor microenvironment;Advanced Drug Delivery Reviews;2022-09

4. Cryogel biomaterials for neuroscience applications;Neurochemistry International;2021-07

5. Traumatic Brain Injuries: Pathophysiology and Potential Therapeutic Targets;Frontiers in Cellular Neuroscience;2019-11-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3