High-dose Intravenous Dalteparin Can be Monitored Effectively Using Standard Coagulation Times

Author:

Wilson James M.1,Gilbert Jerry1,Harlan Mary1,Bracey Arthur2,Allison Paul2,Schooley Chad1,Pinto Kathleen3

Affiliation:

1. Department of Cardiology, St. Luke’s Episcopal Hospital/Texas Heart Institute, Baylor College of Medicine, University of Houston School of Pharmacy, Houston, Texas

2. Department of Pathology, St. Luke’s Episcopal Hospital/Texas Heart Institute, Baylor College of Medicine, University of Houston School of Pharmacy, Houston, Texas

3. Department of Pharmacy, St. Luke’s Episcopal Hospital/Texas Heart Institute, Baylor College of Medicine, University of Houston School of Pharmacy, Houston, Texas

Abstract

The objective of this study was to examine the pharmacokinetics of intravenous dalteparin (Fragmin, Pharmacia-Upjohn, Peapack, NJ) and to assess the accuracy of standard coagulation-based monitoring techniques as an estimate of drug concentration with which to guide dosing. Knowledge of the kinetic behavior of low-molecular-weight heparins (LMWHs) and the possible utility of coagulation times for monitoring may aid in the development of safe and effective dosing algorithms for percutaneous coronary interventions. Twenty normal volunteers were treated at 2-week intervals with each of three intravenous dalteparin doses. Measurement of anti-IIa, anti-Xa, activated partial thromboplastin time (aPTT), activated clotting time (ACT), and low-range ACT was performed at baseline and at seven additional time points over 8 hours. The half-life of intravenous dalteparin is 77 minutes with slight dose-related variation. The aPTT, LR-ACT, and standard ACT are prolonged after dalteparin administration with the increase closely correlated to anti-Xa activity (aPTT, r = 0.85; LR-ACT, r = 0.79). Classification of anticoagulation intensity range using aPTT or LR-ACT in comparison to anti-Xa activity (0.5-0.99, 1.0-1.49, 1.5-2, >2) displays a level of agreement (kappa: aPTT = 0.69, LR-ACT = 0.59) that is comparable to values reported for coagulation time guidance of unfractionated heparin administration. Standard coagulation times are sensitive to the anticoagulant effect of dalteparin with a degree of correlation that suggests their utility for estimating drug concentration during high dose therapy. Trials establishing a relationship between monitoring and clinical efficacy, and the risk/reward of different treatment ranges alone or in combination with GPIIb/IIIa inhibitors and clopidogrel, are necessary.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3