Influence of Different Hydroxyethyl Starch (HES) Formulations on Fibrinogen Measurement in HES-Diluted Plasma

Author:

Adam Susanne1,Karger Ralf2,Kretschmer Volker2

Affiliation:

1. Institute of Transfusion Medicine and Hemostaseology, University Hospital Marburg, Marburg, Germany,

2. Institute of Transfusion Medicine and Hemostaseology, University Hospital Marburg, Marburg, Germany

Abstract

Background: Fibrinogen is the first coagulation factor becoming critical in dilution coagulopathy. Volume replacement in major blood loss is performed with large volumes of crystalloid and colloid solutions. The latter has been shown to compromise accurate photo-optical measurement of fibrinogen. This study determined the influence of different hydroxyethyl starch (HES) formulations. Methods: Citrated plasma samples of 8 healthy volunteers were diluted by 30% or 50% with either HES 10% (200/0.5; HES-200), HES 6% (70/0.5; HES-70), or HES 6% (450/0.7; HES-450). Fibrinogen concentrations were determined by photo-optical measurement (Behring coagulation system [BCS]: derived fibrinogen, or Clauss fibrinogen, calibrated for high [CLS] or low fibrinogen concentrations [CLS-low]) as well as mechanical end point determinations (KC4: CLS-KC4). Measured values were compared with calculated values. Results: On average and across all photo-optical methods, fibrinogen concentrations were overestimated, particularly with HES-200. Hydroxyethyl starch-70 and HES-450 did not differ much from each other. Overestimation was relatively greater for 50% dilutions with all HES formulations. Surprisingly, overestimation was most prominent with CLS-low, the method supposed to most reliably measure low fibrinogen concentrations; overestimation amounted to 92% and 120% with HES-200, 54% and 73% with HES-70, and 51% and 79% with HES-450, for 30% and 50% dilutions, respectively. In contrast, CLS-KC4 always yielded sufficiently accurate results. Conclusions: The study showed that all HES solutions more or less impaired the fibrinogen measurement with the photo-optical method. In particular, overestimation with CLS-low may prevent timely fibrinogen replacement in major blood loss. Hydroxyethyl starch concentration appears to be more relevant for this effect than its molecular size.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3