Photo-Optical Methods Can Lead to Clinically Relevant Overestimation of Fibrinogen Concentration in Plasma Diluted With Hydroxyethyl Starch

Author:

Adam Susanne1,Karger Ralf2,Kretschmer Volker2

Affiliation:

1. Institute of Transfusion Medicine and Hemostaseology, University Hospital Marburg, Marburg, Germany,

2. Institute of Transfusion Medicine and Hemostaseology, University Hospital Marburg, Marburg, Germany

Abstract

Background: Adequate fibrinogen concentration is a crucial component of sufficient perioperative/posttraumatic hemostasis. In major blood loss, large volumes of fluids are being administered, which have been shown to interfere with valid determination of fibrinogen concentration. This may lead to wrong treatment decisions. We studied the variables that cause the discrepancies between measured and true fibrinogen concentrations in samples diluted with volume replacement fluids. Methods: Citrated plasma samples of healthy volunteers were diluted by 30% and 50% with phosphate buffered saline (PBS), hydroxyethyl starch (HES) 10% (200/0.5), or gelatine (GEL). Fibrinogen concentrations of diluted samples were derived from the prothrombin time (PT) and the Clauss method (CLS) was applied. With the latter, several modifications and combinations of detection principles and thrombin reagents were investigated. Values were compared with ‘‘true,’’ that is, calculated values based on the results of undiluted samples for each method. Results: Photo-optical methods resulted in significant overestimation of the fibrinogen concentration in blood diluted with HES, depending on the thrombin reagent used. This was particularly true for modifications of the CLS aimed at measuring low fibrinogen concentrations. Use of another thrombin reagent gave satisfactory results for this modification. The validity of mechanical end point determination methods was considered sufficient and was not influenced by the use of different thrombin reagents. Conclusions: Fibrinogen determination methods used in situations of major blood loss need to be validated with samples containing significant amounts of volume replacement fluids, particularly colloids. Only some combinations of test principle, detection method, and reagents will give valid results.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3