Abstract

Background Percutaneous coronary intervention (PCI) is the main treatment option for acute coronary syndromes (ACS) often related to the progression and rupture of vulnerable plaques. While drug-eluting stents (DES) are now routinely used in PCI, drug-coated balloons (DCB) are a new strategy to PCI and their practice in the treatment of ACS with vulnerable plaques has not been reported. This study aimed to evaluate the safety and efficacy of DCB in ACS complicated with vulnerable plaque lesions. Methods 123 patients were retrospectively analyzed and diagnosed with ACS and given PCI in our Cardiology Department from December 2020 to July 2022. Vulnerable plaques were confirmed by intravenous ultrasound (IVUS) in all patients. According to individual treatment plan, patients were entered into either DCB (n = 55) or DES (n = 68) groups. The results of coronary angiography and IVUS before and immediately after percutaneous coronary intervention were analyzed. The occurrence of major adverse cardiovascular events (MACE) and the results of coronary angiography were also evaluated during follow-up. Results There were no significant differences in baseline clinical characteristics, preoperative minimal luminal diameter (MLD), and preoperative diameter stenosis (DS) between the two groups. Also, there were no differences in IVUS plaque burden (PB), vessel area, and lumen area in the two groups before and immediately after PCI. The efficacy analysis showed that immediately after PCI, the DCB group had smaller MLD and higher degrees of lumen stenosis than the DES group ( P < 0.05). However, during follow-up, no significant differences in MLD and DS were seen in two groups; relatively, late loss in luminal diameter(LLL)in the DCB group was smaller ( P<0.05). Safety analysis showed that during follow-up, 9 patients developed restenosis after DCB implantation while restenosis occurred in 10 patients with DES treatment, no statistical difference in the incidence of restenosis in the two groups. Besides, there was no statistical difference in the incidence of major adverse cardiac events(MACE)during hospitalization and follow-up in the DCB group (7.3% (4/55)) and the DES group (8.8% (6/68)). Conclusion DCB is safe and effective for ACS complicated with vulnerable plaque and has an advantage over DES in LLL.

Funder

the National Natural Science Foundation of China Youth Fund

the Joint project of Medical Science and Technology Research of Henan

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3