Affiliation:
1. Mie Prefectural General Medical Center, Yokkaichi, Japan
2. Mie University Graduate School of Medicine, Tsu, Japan
Abstract
Introduction Although D-dimer is a useful biomarker of thrombosis, there are many D-dimer kits, with high and low fibrinogen and fibrin degradation products (FDP)/ D-dimer ratios. Methods Plasma D-dimer levels were measured using three different kits in critically ill patients to examine the usefulness of such measurements for detecting the thrombotic diseases and determining the correlation with the FDP and FDP/D-dimer ratio. Results Although three D-dimer kits showed marked utility for diagnosing disseminated intravascular coagulation (DIC) and peripheral arterial and venous thromboembolism (PAVTE), the D-dimer levels determined using the three kits varied among diseases. Indeed, one D-dimer kit showed a high FDP/D-dimer ratio, and another kit showed a low FDP/D-dimer ratio. D-dimer kit with low FDP/D-dimer ratio tended to have high cut-off values and low specificity for diagnosing DIC and PAVTE. In D-dimer kit with high FDP/D-dimer ratio, FDP/D-dimer ratios in patients with thrombosis was significantly higher than that in patients without thrombosis. Conclusion All three D-dimer kits show utility for detecting thrombotic diseases. However, the D-dimer levels determined using the kits varied due to differences in the FDP/D-dimer ratio. In combination with the FDP level, a D-dimer kit with a high FDP/D-dimer ratio may be useful.
Funder
Grant-in-Aid from the Japanese Ministry of Health, Labour and Welfare.
Subject
Hematology,General Medicine
Cited by
10 articles.
订阅此论文施引文献