Isolation and Characterization of Contaminants in Recalled Unfractionated Heparin and Low-Molecular-Weight Heparin

Author:

Viskov Christian1,Bouley E.2,Hubert P.2,Martinez Celine2,Herman F.2,Jeske Walter3,Hoppensteadt Debra3,Walenga Jeanine M.3,Fareed Jawed3

Affiliation:

1. sanofi-aventis, Vitry sur Seine, France,

2. sanofi-aventis, Vitry sur Seine, France

3. Loyola University Medical Center, Maywood, Illinois

Abstract

Recently, a contaminant was found in some clinically used unfractionated heparin (UFH) preparations. Administration of this UFH was associated with an increased risk of developing a wide range of adverse effects including death. To further investigate the chemical profile of the contaminant, contaminated batches of UFH were treated by exhaustive nitrous acid depolymerization followed by methanol precipitation to remove heparin oligosaccharides. Because contaminated heparins may have been used as starting material in the production of low-molecular-weight heparins (LMWHs), a similar procedure was carried out using an experimental batch of enoxaparin prepared from contaminated heparin. While high-pressure liquid chromatography (HPLC) analysis of contaminated heparin did not distinguish the presence of the contaminant, it could readily be observed as a high-molecular weight shoulder in the elution profile of contaminated enoxaparin. Digesting contaminated heparin with heparinase-I prior to HPLC analysis showed the presence of a nondigestible component (15%-30% of the mixture). This contaminant was also resistant to degradation by chondroitinases A, B, and C. Proton nuclear magnetic resonance (NMR) indicated that the contaminant was oversulfated chondroitin sulfate (OSCS). Size-exclusion chromatography indicated that the mean molecular weight of the OSCS was 16.8 kD, comparable to that of a synthetic porcine cartilage OSCS preparation that was used as a reference material (17.2 kD). While varying degrees of high-molecular weight dermatan sulfate and other minor impurities were detected, OSCS appeared to be the major contaminant in these preparations. The process involved in the production of enoxaparin does not significantly degrade OSCS.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3