Abstract
Objective: Evaluation of the effect of using a topical hemostatic agent named “ChitoHem®” on different factors on patients undergoing diagnostic coronary angiography. Methods: The present blind, randomized, controlled study included 124 patients randomly divided into 2 groups. In the treatment group following femoral sheath removal, ChitoHem® powder and in the control group conventional hemostatic procedure was applied. Results: In the treatment group, time to hemostasis, ambulation, and the use of sandbag were significantly shorter compared with the control group, respectively (4.6 ± 1.3 vs 12.4 ± 4.4 minutes, 3.5 ± 2.7 vs 23.0 ± 1.73 hours and 1.6 vs 98.4%; P < .05). There were no significant differences in hematoma formation and re-bleeding between the 2 groups. Conclusion: It was exhibited ChitoHem® topical hemostatic powder used on treatment patients undergoing diagnostic coronary angiography was statistically superior at reducing the time to hemostasis and ambulation as well as the use of sandbags compared with manual compression in control group.