Laboratory Assessment of von Willebrand Factor: Altered Interpretation of Laboratory Data, and Altered Diagnosis of von Willebrand's Disease

Author:

Favaloro Emmanuel J.1,Mehrabani Pirooz A.1,Koutts Jerry1

Affiliation:

1. Diagnostic Haemostasis Laboratory, Department of Haematology, Institute of Clinical Pathology and Medical Research (ICPMR), Western Sydney Area Health Service, Westmead, New South Wales, Australia

Abstract

Three laboratory assays for von Willebrand Factor (vWF), namely, (i) a standard "antigen" [antisera-enzyme-linked immunosorbent assay (ELISA)-based] (vWF :Ag), (ii) a standard ristocetin-dependent platelet agglutination procedure (vWF:RCof), and (iii) a newly developed ELISA-based functional vWF collagen binding assay (vWF:CBA), were coevaluated. We (a) assessed their ability to detect vWF under different assay conditions and (b) reevaluated normal vWF reference ranges using citrated plasma from >200 normal individuals. The following effective normal reference ranges were derived: vWF-Ag (40-200%), vWF:CBA (50-400%), and vWF:RCof (45-200%). Based on other laboratory data, caution is indicated in the interpretation of "borderline" or "equivocal" test results (e.g., 35-55%), since these may derive from normal individuals or from vWD patients. In addition, our study shows that selection of different assay conditions, different test plasma dilutions, or different test sample processing methods can also lead to differences in the "apparent" levels of detected vWF. For example, using plasma from 100 normal individuals processed as "test samples," we determined that higher sample dilutions tended to provide lower (dilution factor adjusted) assay results in the case of the vWF:Ag and vWF:CBA, and higher assay results in the case of the vWF.RCof, with greater differences noted in test samples containing higher levels of vWF. The explanation for these findings relate to the assay design. Thus, in the diagnostic laboratory, the standard vWF:Ag, vWF:CBA, and vWF:RCof assays procedures are designed to provide calibration curves that are "upward linear" in the (vWD) clinically important region of 0-50% of normal, with a plateau tending at higher vWF levels. Using these standard methodologies, and standard plasma dilutions, high-vWF level test samples will tend to fall on or near the plateau, and results will be unreliable, with a tendency to be exaggerated the higher the vWF. These findings have particular relevance to research studies measuring vWF in patients suffering various clinical conditions (e.g., thrombotic thrombocytopenic purpura, diabetes, renal failure) where higher than normal levels of vWF may be anticipated. In these cases, laboratory-derived vWF levels could be "misrepresented" if the study design did not take into account the need to revise the vWF testing procedure. Key Words: von Willebrand factor-von Willebrand's disease—Laboratory assessment-Normal ranges—Reference ranges—Diagnosis.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Reference37 articles.

1. Giddings JC, Peake IR The investigation of factor VIII deficiency. In: Thompson JM, ed. Blood coagulation and haemostasis . New York: Churchill Livingstone , 1985:135.

2. Structure-function relationship of human von Willebrand factor

3. von Willebrand factor.

4. Commentary: a new classification for von Willebrand disease

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3