Scanning microdensitometry of objects small relative to the wavelength of light.

Author:

Goldstein D J

Abstract

Diffraction effects may have to be taken into account in microdensitometry when dealing with relatively dark specimens even an order of magnitude larger than the wavelength of light, and become progressively more important with smaller objects. According to geometrical optical theory, when scanning across the straight edge of a uniformly absorbing, semi-infinite object the distribution error per scan line is directly proportional to the diameter of the measuring-spot. Diffraction theory predicts similar results for measuring-spots larger than about 3 times the wavelength of light, but a significant error per scan line with very small or even infinitesimal measuring-spots. Diffraction theory further indicates that point absorbance measurements can be 95 + % accurate in the centers of 6.25, 2.5, and 2.0 microns diameter disks with absorbances respectively up to about 1.0, 0.39, and 0.25, but that this accuracy is unattainable with any object less than 1.25 microns in diameter. Scanning, integrating absorbance measurements are of somewhat lower accuracy than central point measurements with relatively large objects, e.g., they are only about 89% accurate with a 6 micron diameter object of absorbance 1.0. With very small objects, diffraction theory shows distribution error to be almost independent of the size of the scanning spot, and with an object of less than about 0.125 micron diameter the apparent integrated absorbance predicted by diffraction theory is effectively identical with that predicted by geometrical theory for an infinitesimal object scanned with a finite measuring-spot, i.e., it is the product of the object area and 0.4343 (1-It), where It is the true transmission. Scanning microdensitometry of objects of very low true absorbance is effectively free from distribution error. In practice, distribution error can be reduced by using an off-peak wavelength, by reducing the area illuminated, and by routine measurement and offsetting of apparent glare (some of which is actually due to diffraction). Little or nothing is to be gained by using a measuring-spot smaller than about one-quarter the wavelength of light.

Publisher

SAGE Publications

Subject

Histology,Anatomy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3