An extensive CO2 concentration monitoring activity was carried out in a middle school located in Rome. Objective of the study was to evaluate the indoor air quality in eight classrooms during class occupation and to evaluate the ventilation rates of a natural trickle ventilation system, through an interactive approach involving the pupils. The analysis was conducted in two phases: a long-term analysis that consisted of evaluating the CO2 concentration and indoor air temperature in each classroom during the 2009/2010 scholastic year to obtain a snapshot of the indoor environment and a short-term testing carried out in 4 days in February 2010, involving the pupils in the monitoring activity. The campaign was performed during the teaching hours and students registered the air exchange events (opening and closing of windows and door) during the class hours. The correlation of the air exchange events recorded by the students with the CO2 concentration level recorded every minute and the opening and closing control of the trickle ventilation system allowed the evaluation of the ventilation rate of the system. The interactive evaluation approach gave the conclusion that the system alone could not completely fulfil its performance requirement.

Publisher

SAGE Publications

Subject

Public Health, Environmental and Occupational Health

Reference29 articles.

1. Wargocki P, Wyon DP, Ole Fanger P: Productivity is affected by the air quality in offices. In Proceedings of Healthy Buildings 2000, 6-10 August 2000 - Espoo, Finland; Vol. 1, pp. 635–640.

2. Clements-Croome D, Baizhan L: Productivity and indoor environment. In Proceedings of Healthy Buildings 2000, 6-10 August 2000 - Espoo, Finland; Vol 1, pp. 629–634.

3. Fisk WJ: Review of health and productivity gains from better IEQ. In Proceedings of Healthy Buildings 2000, 6-10 August 2000 - Espoo, Finland; Vol. 4 pp. 23–33.

4. Neurobehavioral approach for evaluation of office workers' productivity: The effects of room temperature

5. Use of neurobehavioral tests to evaluate the effects of indoor environment quality on productivity

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3