Abstract
We investigate the seismic response of liquid storage tanks isolated by lead-rubber bearings. The force-deformation behavior of the bearings is considered as bi-linear modeled by the Wen equation. The continuous liquid mass of the tank is modeled as a sloshing mass, impulsive mass and rigid mass. The corresponding stiffness associated with these masses has been worked out depending upon the properties of the tank wall and liquid mass. The governing equations of motion of the three-degrees-of-freedom model of the isolated liquid storage tank are derived. Since the force-deformation behavior of the bearings is non-linear, as a result, the seismic response is obtained using the Newmark step-by-step method under several recorded earthquake ground motions. The responses of two types of tanks, namely slender and broad, are compared with the corresponding response without an isolation system in order to investigate the effectiveness of the isolation system. A parametric study is also carried out to study the effects of important system parameters on the effectiveness of seismic isolation for liquid storage tanks. The various important parameters considered are the aspect ratio of the tank, period, damping and the yield strength of the isolation system. It has been observed that the seismic isolation of the tanks is quite effective and the response of isolated liquid storage tanks is significantly influenced by the above system parameters. There is an optimum value of isolation damping for which the base shear in the tank attains the minimum value. Therefore, increasing the bearing damping beyond a certain value decreases the bearing and sloshing displacements but it increases the base shear.
Subject
Mechanical Engineering,Mechanics of Materials,Aerospace Engineering,Automotive Engineering,General Materials Science
Reference16 articles.
1. Seismic Isolation: History, Application, and Performance—A World View
2. Shake Table Test of Cylindrical Water Tanks in Base‐Isolated Structures
3. Epstein, H.I. 1976, “Seismic design of liquid storage tanks,” Journal of Structural Division, ASCE 102, 1659-1673 .
4. Vibration studies and tests of liquid storage tanks
5. Housner, G.W. 1957, “Dynamic pressures on accelerated fluid containers,” Bulletin of Seismological Society of America 1, 15-37 .
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献