Four-dimensional digital subtraction angiography for the vascular anatomical diagnosis of dural arteriovenous malformation: Comparison with the conventional method

Author:

Ishikawa Kojiro1ORCID,Nishihori Masahiro1ORCID,Izumi Takashi1,Oshima Ryosuke1,Uemura Takeshi2,Kanamori Fumiaki1,Uda Kenji1,Yokoyama Kinya1,Araki Yoshio1,Saito Ryuta1

Affiliation:

1. Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan

2. Department of Radiological Technology, Nagoya University Hospital, Aichi, Japan

Abstract

Background Two-dimensional digital subtraction angiography (2D-DSA) and conventional three-dimensional digital subtraction angiography (3D-DSA) are used for the detailed analysis of dural arteriovenous fistula (DAVF). Recently, four-dimensional digital subtraction angiography (4D-DSA), a novel technology, has been attracting attention. The current study aimed to evaluate the capability of 4D-DSA in assessing anatomical angioarchitecture in DAVF. Methods In total, 10 consecutive patients with DAVF who underwent 3D-DSA and 4D-DSA at a single institution were included in the analysis. Initially, one-slice multiplanar reconstruction (MPR) images obtained via 4D-DSA and 3D-DSA were compared to investigate the visibility of the feeding artery, fistulous point, and draining vein. Next, 4D-DSA images alone were compared and evaluated with and the MPR images of conventional 3D-DSA in terms of diagnosis of the angioarchitecture. Results In total, six men and four women (with a mean age of 65.6 ± 10.0 years) were included in the study. The MPR image obtained via 3D-DSA had a significantly better visibility of the feeding artery and fistulous point than that acquired via 4D-DSA ( p < 0.05). As for the draining vein, the score was equivalent and not significant. The diagnosis of the vascular architecture of only 4D-DSA images was nearly equivalent to that of MPR images of 3D-DSA. There were no inter-rater differences. Conclusion The MPR images obtained via 4D-DSA may be slightly inferior to those acquired via 3D-DSA in identifying fine angioarchitecture in DAVF. However, they were comparable in terms of diagnostic accuracy.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3