Quantitative radial force measurements of Woven EndoBridge devices

Author:

Kutbay Ugurhan1,Algin Oktay234ORCID

Affiliation:

1. Department of Electrical and Electronics Engineering, Faculty of Engineering, Gazi University, Ankara, Turkey

2. Interventional MR Clinical R&D Institute, Ankara University, Ankara, Turkey

3. National MR Research Center (UMRAM), Bilkent University, Ankara, Turkey

4. Radiology Department, Ankara University, Medical Faculty, Ankara, Turkey

Abstract

Background Lateral/radial forces and the mechanical properties of Woven EndoBridge (WEB) devices have significant importance for therapeutic success. In other words, adequate apposition of the lateral wall of a cerebral aneurysm is critical for preventing recurrence or re-rupture risk. Objective This study aimed to investigate the pressure values applied by different WEB devices to the lateral walls of aneurysms and the relationships between these pressure measurements and the diameters of WEB devices. Methods By placing four WEB devices of different sizes and types between two rigid metal plates, the lateral forces applied by these WEB devices to plates of different apertures were measured quantitatively. We tested a single device of each size over multiple periods. The total number of examined WEB devices is four. Results There was a significant negative relationship between plate distances and pressure values (correlation coefficient:–0.956, p = 0.000). The lateral wall apposition pressure of a 4- or 5-mm aperture size was higher than a 6-mm aperture size for SL-type WEB devices with a 7-mm diameter. Similarly, the lateral wall apposition pressure detected for a 3- or 3.5-mm aperture size was higher than a 4-mm aperture size for W5-4.5-3 and W5-5-3.6. It was observed that maximum lateral wall pressure was detected in plate measurements of SLS-type devices compared to SL-type devices. The diameter and height values of 3 of the 4 unconstrained WEB devices analyzed differed from the catalog values. Conclusion It seems that SLS-type devices apply more pressure on the aneurysm's lateral borders than SL-type devices.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3